pdu2GroupCurrent
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.7.3.1.1.12
Object
column
mandatory
Integer32
A group current measurement value. Units are milliamps.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.7.3.1.1.12- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- pdu2GroupEntry
- Table
- pdu2GroupTable
- Siblings
- 26
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdu2GroupIndex mandatory Index for the Pdu2GroupEntry table. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.1 |
| pdu2GroupVoltageThUpperCritical mandatory Upper critical threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.10 |
| pdu2groupCurrentRating mandatory Rated current capacity of the group. Units are milliamps. A negative
value indicates that the hardware current capacity is unknown (it
will always be unknown for custom groups). | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.11 |
| pdu2GroupCurrentThStatus mandatory Status of the measured group current relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.7.3.1.1.13 |
| pdu2GroupCurrentThLowerWarning mandatory Lower warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.14 |
| pdu2GroupCurrentThLowerCritical mandatory Lower critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.15 |
| pdu2GroupCurrentThUpperWarning mandatory Upper warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.16 |
| pdu2GroupCurrentThUpperCritical mandatory Upper critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.17 |
| pdu2GroupCurrentCrestFactor mandatory Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.18 |
| pdu2GroupCurrentPercentLoad mandatory Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not avail… | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.19 |
| pdu2GroupName mandatory A descriptive name for the group. | column | OctetString | .1.3.6.1.4.1.232.165.7.3.1.1.2 |
| pdu2GroupPowerVA mandatory A group VA value. Units are VA. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.20 |
| pdu2GroupPowerWatts mandatory A group Watts value. Units are Watts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.21 |
| pdu2GroupPowerWattHour mandatory A Watt-Hour value for each section. Units are WH. This value can be reset to 0
using GUI. In that case, the pdu2GroupPowerWattHourTimer will be reset as well.
A negative val… | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.22 |
| pdu2GroupPowerWattHourTimer mandatory Timestamp of when group Watt-hours (groupWh) was last reset. | column | OctetString | .1.3.6.1.4.1.232.165.7.3.1.1.23 |
| pdu2GroupPowerFactor mandatory A group PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned as 920.
A negative value indicates that thi… | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.24 |
| pdu2GroupPowerVAR mandatory A group VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.25 |
| pdu2GroupOutletCount mandatory The number of outlets in each group (breaker). | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.26 |
| pdu2GroupBreakerStatus mandatory Only applicable to groups with breaker. Indicates whether a breaker is turned
off or on. | column | Enumeration | .1.3.6.1.4.1.232.165.7.3.1.1.27 |
| pdu2GroupType mandatory The type of the group. (5) has no breaker | column | Enumeration | .1.3.6.1.4.1.232.165.7.3.1.1.3 |
| pdu2GroupVoltageMeasType mandatory Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phas… | column | Enumeration | .1.3.6.1.4.1.232.165.7.3.1.1.4 |
| pdu2GroupVoltage mandatory Units are millivolts. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.5 |
| pdu2GroupVoltageThStatus mandatory Status of the measured group voltage relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.7.3.1.1.6 |
| pdu2GroupVoltageThLowerWarning mandatory Lower warning threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.7 |
| pdu2GroupVoltageThLowerCritical mandatory Lower critical threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.8 |
| pdu2GroupVoltageThUpperWarning mandatory Upper warning threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.3.1.1.9 |