cpqDaPhyDrvFunctTest1
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.5.1.1.23
Object
Functional Test 1.
This provides information about a series of tests that indicate
how well a physical drive works. These tests compare the way the
physical drive currently operates when performing various tasks
with the way it worked when it was new.
A percent value is displayed that represents how the drive works
currently when compared to how the drive worked when new. New
drives operate at the 100 percent level. By default, if the
current value is less than or equal to 80 percent, a problem may
exist.
If you suspect a problem, schedule server down time to run
diagnostics to verify that a problem exists.
If the value cannot be determined, it is set to 4,294,967,295.
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.5.1.1.23- Type
- column
- Access
- readonly
- Status
- obsolete
- Parent
- cpqDaPhyDrvEntry
- Table
- cpqDaPhyDrvTable
- Siblings
- 79
Syntax
RFC1155-SMIGauge
- Source
- RFC1155-SMIGauge
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqDaPhyDrvCntlrIndex mandatory Drive Array Physical Drive Controller Index.
This index maps the physical drive back to the controller to
which it is attached. The value of this index is the same … | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.1 |
| cpqDaPhyDrvHReads mandatory Sectors Read (high).
The phyDrvHReads and the phyDrvReads together shows the total
number of sectors read from the physical disk drive during the
reference time (ph… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.10 |
| cpqDaPhyDrvReads mandatory Sectors Read (low).
The phyDrvHReads and the phyDrvReads together shows
the total number of sectors read from the physical disk drive
during the reference time (phy… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.11 |
| cpqDaPhyDrvHWrites mandatory Sectors Written (high).
The phyDrvHWrites and the phyDrvWrites together shows the
total number of sectors written to the physical disk drive
during the reference ho… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.12 |
| cpqDaPhyDrvWrites mandatory Sectors Written (low).
The phyDrvHWrites and the phyDrvWrites together
shows the total number of sectors written to the physical
disk drive during the reference hou… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.13 |
| cpqDaPhyDrvHSeeks mandatory Total Seeks (high).
The phyDrvHSeeks and the phyDrvSeeks together shows the total
number of seek operations performed by the physical disk drive
during the referenc… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.14 |
| cpqDaPhyDrvSeeks mandatory Total Seeks (low).
The phyDrvHSeeks and the phyDrvSeeks together shows the total
number of seek operations performed by the physical disk drive
during the reference… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.15 |
| cpqDaPhyDrvHardReadErrs mandatory Hard Read Errors.
This shows the number of read errors that have occurred on a
drive that could not be recovered by a physical drive`s Error
Correction Code (ECC) a… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.16 |
| cpqDaPhyDrvRecvReadErrs mandatory Recovered Read Errors.
This shows the number of read errors corrected through physical
drive retries during the reference time (phyDrvRefTime).
Over … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.17 |
| cpqDaPhyDrvHardWriteErrs mandatory Hard Write Errors.
This shows the number of write errors that could not be recovered
by a physical drive during the reference time (phyDrvRefTime).
O… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.18 |
| cpqDaPhyDrvRecvWriteErrs mandatory Recovered Write Errors.
This shows the number of write errors corrected through physical
drive retries or recovered by a physical drive during the
reference time (p… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.19 |
| cpqDaPhyDrvIndex mandatory Drive Array Physical Drive Index.
This index is used for selecting the physical drive table entry.
This number, along with the cpqDaPhyDrvCntlrIndex uniquely
identi… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.2 |
| cpqDaPhyDrvHSeekErrs mandatory Seek Errors (High).
The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
total number of times that the physical disk drive detected a
seek error during th… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.20 |
| cpqDaPhyDrvSeekErrs mandatory Seek Errors (low).
The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
total number of times that the physical disk drive detected a
seek error during the reference hour… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.21 |
| cpqDaPhyDrvSpinupTime mandatory Spin up Time in tenths of seconds.
This is the time it takes for a physical drive to spin up to full
speed.
Disks require time to gain momentum and r… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.22 |
| cpqDaPhyDrvFunctTest2 obsolete Functional Test 2.
This provides information about a series of tests that indicate
how well a physical drive works. These tests compare the way the
physical drive c… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.3.2.5.1.1.24 |
| cpqDaPhyDrvFunctTest3 obsolete Functional Test 3.
This provides information about a series of tests that indicate
how well a physical drive works. These tests compare the way the
physical drive c… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.3.2.5.1.1.25 |
| cpqDaPhyDrvDrqTimeouts mandatory DRQ Timeouts.
The number of times that a physical drive continued to request
data, but did not get a command completion during the reference
time (phyDrvRefTime). … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.26 |
| cpqDaPhyDrvOtherTimeouts mandatory Other Timeouts.
The number of times that a physical drive did not respond with an
interrupt within a controller-defined period of time after a
command had been issu… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.27 |
| cpqDaPhyDrvSpinupRetries mandatory Spin up Retries.
The number of times that a physical drive had to retry to spin up
before successfully achieving operating speed during the reference
time (phyDrvRe… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.28 |
| cpqDaPhyDrvBadRecvReads mandatory Recovery Failed (Bad) Read Error.
The number of times a read error occurred while performing
Automatic Data Recovery from this physical drive to another
drive durin… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.29 |
| cpqDaPhyDrvModel mandatory Physical Drive Model.
This is a text description of the physical drive. The text that
appears depends upon who manufactured the drive and the drive
type.
… | column | OctetString | .1.3.6.1.4.1.232.3.2.5.1.1.3 |
| cpqDaPhyDrvBadRecvWrites mandatory Recovery Failed (Bad) Write Error.
The number of times a write error occurred while performing
Automatic Data Recovery from another drive to this physical
drive dur… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.30 |
| cpqDaPhyDrvFormatErrs mandatory Format Error.
The number of times a format operation failed when the controller
attempted to remap a bad sector during the reference time
(phyDrvRefTime). Zero ind… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.31 |
| cpqDaPhyDrvPostErrs mandatory Power On Self Test (Post) Error.
The number of times that a physical drive failed its self test
during the reference time (phyDrvRefTime).
The physic… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.32 |
| cpqDaPhyDrvNotReadyErrs mandatory Drive Not Ready Errors.
The number of times the physical drive failed after the spin up
command was issued during the reference time (phyDrvRefTime).
When the spin … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.33 |
| cpqDaPhyDrvReallocAborts mandatory Physical Drive Reallocation Aborts.
The number of times the physical drive has failed due to an error
that occurred when the controller was trying to reallocate a b… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.34 |
| cpqDaPhyDrvThreshPassed mandatory Physical Drive Factory Threshold Passed (Exceeded).
When the drive is shipped, certain thresholds have been set to
monitor performance of the drives. For example, … | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.35 |
| cpqDaPhyDrvHasMonInfo mandatory Physical Drive Has Monitor Information.
All of the physical disk table fields except for the physical
disk status (phyDrvStatus) and the bay location
(phyDrvBayLoca… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.36 |
| cpqDaPhyDrvCondition mandatory The condition of the device.
This value represents the overall condition of this physical
drive. | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.37 |
| cpqDaPhyDrvHotPlugs mandatory Physical Drive Hot Plug Count.
This value indicates the number of times this physical drive
was hot-plugged (removed) from a ProLiant Storage System.
This is not su… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.38 |
| cpqDaPhyDrvMediaErrs mandatory Physical Drive Media Failure Count.
This value indicates the number of times this physical drive
was failed due to unrecoverable media errors. This is not
supporte… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.39 |
| cpqDaPhyDrvFWRev mandatory Physical Drive Firmware Revision.
This shows the physical drive revision number.
If the firmware revision is not present, you have not properly
initi… | column | OctetString | .1.3.6.1.4.1.232.3.2.5.1.1.4 |
| cpqDaPhyDrvHardwareErrs mandatory Physical Drive Hardware Error Count.
This value indicates the number of times this physical drive
returned a bad hardware status. The drive may be failed if
retries… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.40 |
| cpqDaPhyDrvAbortedCmds mandatory Physical Drive Aborted Command Failures.
This value indicates the number of times this physical drive
was failed due to aborted commands that could not be retried
s… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.41 |
| cpqDaPhyDrvSpinUpErrs mandatory Physical Drive Spin-Up Failure Count.
This value indicates the number of times this physical drive
was failed due to a failure of a spin-up command. This is not
su… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.42 |
| cpqDaPhyDrvBadTargetErrs mandatory Physical Drive Bad Target Count.
This value indicates the number of times this physical drive
performed some action that did not conform to the SCSI-2 bus
protocol.… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.43 |
| cpqDaPhyDrvLocation obsolete Drive Physical Location.
This is the physical location of where the drive is located.
The following values are defined:
other(1)
The location of th… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.44 |
| cpqDaPhyDrvSize mandatory Physical Drive Size in MB.
This is the size of the physical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manu… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.45 |
| cpqDaPhyDrvBusFaults mandatory Physical Drive Bus Fault Count.
This value indicates the number of times that a bus fault was
detected for the drive by the controller. This is not supported
by th… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.46 |
| cpqDaPhyDrvIrqDeglitches mandatory Physical Drive IRQ Deglitch Count.
This is not supported by the IDA, IDA Expansion, or IDA-2
controllers. | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.47 |
| cpqDaPhyDrvHotPlug mandatory Physical Drive Hot Plug Support Status.
The following values are defined:
other(1)
The Insight Agent is unable to determine if this drive
support… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.48 |
| cpqDaPhyDrvPlacement mandatory Physical Drive Placement.
The following values are defined:
other(1)
The agent is unable to determine if the drive is internal or
external to the… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.49 |
| cpqDaPhyDrvBay mandatory Physical Drive Bay Location.
This value matches the bay location where the physical drive has
been installed. For a SCSI drive, this is the SCSI ID of the
drive. … | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.5 |
| cpqDaPhyDrvBusNumber mandatory Physical Drive SCSI Bus Number.
The bus number indicates to which SCSI bus this physical
drive is attached. The first instance is one and increments
for each SCSI … | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.50 |
| cpqDaPhyDrvSerialNum mandatory Physical Drive Serial Number.
This is the serial number assigned to the physical drive.
This value is based upon the serial number as returned by the
SCSI inquiry c… | column | OctetString | .1.3.6.1.4.1.232.3.2.5.1.1.51 |
| cpqDaPhyDrvPreFailMonitoring mandatory Drive Array Physical Drive Predictive Failure Monitoring.
The following values are defined:
other(1)
The agent is unable to determine if the drive … | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.52 |
| cpqDaPhyDrvCurrentWidth mandatory Drive Array Physical Drive Current Width.
The following values are defined:
other(1)
The agent is unable to determine the current negotiated data
… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.53 |
| cpqDaPhyDrvCurrentSpeed mandatory Drive Array Physical Drive Current Data Transfer Speed.
The following values are defined:
other(1)
The agent is unable to determine the current neg… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.54 |
| cpqDaPhyDrvFailureCode mandatory Drive Array Physical Drive Failure Code.
This value is the drive failure reason code returned by the
array firmware. It is valid only when the drive is failed.
If … | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.55 |
| cpqDaPhyDrvBlinkTime mandatory Physical Drive Blink Time Count.
This value indicates the amount of time, in tenths of a second,
that the physical drive LEDs will continue to blink. A value of
ze… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.56 |
| cpqDaPhyDrvSmartStatus mandatory Physical Drive S.M.A.R.T Status.
The following values are defined:
other(1)
The agent is unable to determine if the status of S.M.A.R.T
predictiv… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.57 |
| cpqDaPhyDrvConfigurationStatus mandatory Physical Drive Configuration Status.
The following values are defined:
other(1)
The agent is unable to determine the configuration status of
this… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.58 |
| cpqDaPhyDrvRotationalSpeed mandatory Drive Array Physical Drive Rotational Speed.
The following values are defined:
other(1)
The agent is unable to determine the rotational speed for
… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.59 |
| cpqDaPhyDrvStatus mandatory Physical Drive Status.
This shows the status of the physical drive.
The following values are valid for the physical drive status:
… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.6 |
| cpqDaPhyDrvType mandatory Physical Drive Type.
The following values are defined:
other(1)
The agent is unable to determine the type for this drive.
parallelSc… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.60 |
| cpqDaPhyDrvSataVersion mandatory Physical Drive SATA Version.
The following values are defined:
other(1)
The agent is unable to determine the SATA version for this
drive or it is… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.61 |
| cpqDaPhyDrvHostConnector mandatory Physical Drive Host Connector.
This is the host connector to which the drive is ultimately
attached. If the host connector cannot be determined, the agent
will ret… | column | OctetString | .1.3.6.1.4.1.232.3.2.5.1.1.62 |
| cpqDaPhyDrvBoxOnConnector mandatory Physical Drive Box on Connector.
The box on connector indicates to which box instance this
physical drive belongs. The instances start at one and increment for
eac… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.63 |
| cpqDaPhyDrvLocationString mandatory Physical Drive Location String.
This string describes the location of the drive in relation to
the controller. If the location string cannot be determined,
the age… | column | OctetString | .1.3.6.1.4.1.232.3.2.5.1.1.64 |
| cpqDaPhyDrvNegotiatedLinkRate mandatory Drive Array Physical Drive Negotiated Link Rate.
The following values are defined:
other(1)
The agent is unable to determine the negotiated link ra… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.65 |
| cpqDaPhyDrvNcqSupport mandatory Drive Array Physical Drive Native Command Queueing.
The following values are defined:
other(1)
The agent is unable to determine the NCQ configurati… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.66 |
| cpqDaPhyDrvPhyCount mandatory Drive Array Physical Drive PHY Count.
This value indicates how many PHYs exist on SAS/SATA disk. For
parallel SCSI disks, this value is set to -1. | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.67 |
| cpqDaPhyDrvMultipathAccess mandatory Drive Array Physical Drive Multi-path Access Status.
This indicates if this physical drive has been configured to have
and currently still has more than one I/O pat… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.68 |
| cpqDaPhyDrvMediaType mandatory Drive Array Physical Drive Media Type.
The following values are defined:
other(1)
The instrument agent is unable to determine the media type of phy… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.69 |
| cpqDaPhyDrvFactReallocs mandatory This shows the number of spare sectors available for
remapping at the time the physical drive was shipped.
The physical drive will use these spare sectors for remapping
bad sector… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.7 |
| cpqDaPhyDrvCurrentTemperature mandatory Drive Array Physical Drive Current Temperature.
This is the temperature of the physical drive in degrees Celsius.
The field will contain -1 if the drive temperatu… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.70 |
| cpqDaPhyDrvTemperatureThreshold mandatory Drive Array Physical Drive Temperature Threshold.
This is the temperature in degrees Celsius at which the drive says it is
overheated. The field will contain -1 if… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.71 |
| cpqDaPhyDrvMaximumTemperature mandatory Drive Array Physical Drive Maximum Temperature.
This is the maximum temperature in degrees Celsius that the drive has
reached. The field will contain -1 if the ma… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.72 |
| cpqDaPhyDrvSSDWearStatus mandatory Drive Array Physical Drive Solid State Disk Wear Status.
This shows the wear status of the solid state physical drive.
The following values are valid… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.73 |
| cpqDaPhyDrvPowerOnHours mandatory Drive Array Physical Drive Power On Hours.
This is the total number of hours that the physical disk
has been powered on. This value will be 4,294,967,295 if the di… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.74 |
| cpqDaPhyDrvSSDPercntEndrnceUsed mandatory Drive Array Physical Drive Solid State Percent Endurance Used.
This value specifies the hundredths of the percentage of solid state
disk life used. The value of th… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.3.2.5.1.1.75 |
| cpqDaPhyDrvSSDEstTimeRemainingHours mandatory Drive Array Physical Drive Solid State Estimated Time Remaining In
Hours.
This is the estimated total number of hours that the solid state
physical disk has remaini… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.76 |
| cpqDaPhyDrvAuthenticationStatus mandatory Drive Array Physical Drive Authentication Status.
The following values are defined:
Other (1)
Indicates that the instrument agent can not determine… | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.77 |
| cpqDaPhyDrvSmartCarrierAppFWRev mandatory Physical Drive Smart Carrier Application Firmware Revision.
This displays the physical drive smart carrier application
firmware revision number.
This… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.78 |
| cpqDaPhyDrvSmartCarrierBootldrFWRev mandatory Physical Drive Smart Carrier Bootloader Firmware Revision.
This displays the physical drive smart carrier bootloader
firmware revision number.
This v… | column | Integer32 | .1.3.6.1.4.1.232.3.2.5.1.1.79 |
| cpqDaPhyDrvUsedReallocs mandatory Physical Drive Used Reallocated Sectors.
This shows the number of sectors of the reallocation area that
have been used by the physical drive.
To see … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.8 |
| cpqDaPhyDrvEncryptionStatus mandatory Physical Drive Encryption Status.
The physical drive`s encryption status. The following values are
valid:
other (1)
Indicates that the instrument … | column | Enumeration | .1.3.6.1.4.1.232.3.2.5.1.1.80 |
| cpqDaPhyDrvRefHours mandatory Reference Time in hours.
This shows the total number of hours that a physical drive has
been in operation since the drive was stamped. The drive will have
either b… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.5.1.1.9 |