cpqDaPhyDrvErrDesc

CPQIDA-MIB · .1.3.6.1.4.1.232.3.2.5.2.1.15

Object

column mandatory Enumeration
The index used to display an error associated with a physical drive.
              
This number refers to an entry in a list of error strings
enumerating the possible physical drive errors associated with
a particular physical disk drive.
              
The valid values are:
              
DriveFailure (1)
  The Management Station should display the following string:
  `Drive Failure`.
              
CommFailure(2)
  The Management Station should display the following string:
  `Communication Failure`.
              
DriveIOError(3)
  The Management Station should display the following string:
  `Drive I/O Error`.
              
SCSICommError(4)
  The Management Station should display the following string:
  `SCSI Communication Error`.
              
UpgradeRequired(5)
  The Management Station should display the following string:
  `Configuration Utility or OS upgrade required`.
              
DriveWriteProtected(6)
  The Management Station should display the following string:
  `Drive Write Protected - Check Drive Jumpers`.
              
InvalidRequest(7)
  The Management Station should display the following string:
  `Invalid Request`.
              
SCSIMessageError(8)
  The Management Station should display the following string:
  `SCSI Message Error`.
              
ControllerFailure(9)
  The Management Station should display the following string:
  `Controller Failure`.
              
InternalExternalConflict(10)
  The Management Station should display the following string:
  `Internal/External Conflict on Port 1`.
              
InternalDriveFailure(11)
  The Management Station should display the following string:
  `Internal Drive Failure`.
              
SCSIErrorOutOfRange(12)
  The Management Station should display the following string:
  `SCSI Error, Sense Code = %xh` where %x is the value of the
   cpqDaPhyDrvSenseCode object.  This index will only be provided
   if the specified object exceeds the valid range.
              
CAMErrorOutOfRange(13)
  The Management Station should display the following string:
  `CAM Error, CAM status =%xh` where %x is the value of the
  cpqDaPhyDrvCamStatus object.  This index will only be provided
  if the specified object exceeds the valid range.
              
ErrorTypeOutOfRange(14)
  The Management Station should display the following string:
  `Error type =%xh` where %x is the value of the
  cpqDaPhyDrvErrType object.  This index will only be provided
  if the specified object exceeds the valid range.

Context

MIB
CPQIDA-MIB
OID
.1.3.6.1.4.1.232.3.2.5.2.1.15
Type
column
Access
readonly
Status
mandatory
Parent
cpqDaPhyDrvErrEntry
Table
cpqDaPhyDrvErrTable
Siblings
14

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects