Array Logical Drive Corrected Reads.
This is the total number of read commands sent to the specified
logical drive which had to be corrected by fault tolerance. This
number is reset each time the device driver is loaded for this
logical drive.
If the number of corrected reads is higher than normal for a
particular system, check the physical drive screen for abnormal
activity. There may be a problem with a drive. If you suspect
that a problem exists, schedule server down time to run
diagnostics on the monitored system.
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.1.1.5.1.5- Type
- column
- Access
- readonly
- Status
- obsolete
- Parent
- cpqDaNw3xDriverStatEntry
- Table
- cpqDaNw3xDriverStatTable
- Siblings
- 7
Syntax
RFC1155-SMICounter
- Source
- RFC1155-SMICounter
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqDaNw3xCntlrIndex obsolete Array Controller Index.
This maps the logical drives into their respective controllers.
This controller index matches the controller group entries. | column | Integer32 | .1.3.6.1.4.1.232.3.2.1.1.5.1.1 |
| cpqDaNw3xLogDrvIndex obsolete Array Logical Drive Index.
This is the logical drive number which keeps track of multiple
instances of logical drives which are on the same controller.
For each con… | column | Integer32 | .1.3.6.1.4.1.232.3.2.1.1.5.1.2 |
| cpqDaNw3xTotalReads obsolete Array Logical Drive Total Reads.
This shows the total number of reads performed by the IDA device
driver to this logical drive. This number is reset each time the
… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.1.1.5.1.3 |
| cpqDaNw3xTotalWrites obsolete Array Logical Drive Total Writes.
This shows the total number of writes performed by the IDA device
driver to this logical drive. This number is reset each time th… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.1.1.5.1.4 |
| cpqDaNw3xCorrWrites obsolete Array Logical Drive Corrected Writes.
This is the total number of write commands sent to the specified
logical drive which had to be corrected by fault tolerance. … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.1.1.5.1.6 |
| cpqDaNw3xFatalReads obsolete Array Logical Drive Fatal Reads.
This is the total number of read commands sent to the specified
logical drive which failed. This number is reset each time the
dev… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.1.1.5.1.7 |
| cpqDaNw3xFatalWrites obsolete Array Logical Drive Fatal Writes.
This is the total number of write commands sent to the specified
logical drive which failed. This number is reset each time the
d… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.1.1.5.1.8 |