cpqDaLogDrvStatus
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.3.1.1.4
Object
column
mandatory
Enumeration
Logical Drive Status.
The logical drive can be in one of the following states:
Ok (2)
Indicates that the logical drive is in normal operation mode.
Failed (3)
Indicates that more physical drives have failed than the
fault tolerance mode of the logical drive can handle without
data loss.
Unconfigured (4)
Indicates that the logical drive is not configured.
Recovering (5)
Indicates that the logical drive is using Interim Recovery Mode.
In Interim Recovery Mode, at least one physical drive has
failed, but the logical drive`s fault tolerance mode lets the
drive continue to operate with no data loss.
Ready Rebuild (6)
Indicates that the logical drive is ready for Automatic Data
Recovery. The physical drive that failed has been replaced,
but the logical drive is still operating in Interim Recovery
Mode.
Rebuilding (7)
Indicates that the logical drive is currently doing Automatic
Data Recovery. During Automatic Data Recovery, fault tolerance
algorithms restore data to the replacement drive.
Wrong Drive (8)
Indicates that the wrong physical drive was replaced after a
physical drive failure.
Bad Connect (9)
Indicates that a physical drive is not responding.
Overheating (10)
Indicates that the drive array enclosure that contains the
logical drive is overheating. The drive array is still
functioning, but should be shutdown.
Shutdown (11)
Indicates that the drive array enclosure that contains the
logical drive has overheated. The logical drive is no longer
functioning.
Expanding (12)
Indicates that the logical drive is currently undergoing a
transformation (expansion, shrinkage or movement). During
transformation, fault tolerance algorithms redistribute logical
drive data according to the transformation operation selected.
Not Available (13)
Indicates that the logical drive is currently unavailable.
If a logical drive is expanding and the new configuration
frees additional disk space, this free space can be
configured into another logical volume. If this is done,
the new volume will be set to not available.
Queued For Expansion (14)
Indicates that the logical drive is ready for transformation
(expansion, shrinkage or movement). The logical drive is in the
queue for transformation.
Multi-path Access Degraded (15)
Indicates that previously all disk drives of this logical
drive had more than one I/O path to the controller, but now
one or few of them have only one I/O path.
Erasing (16)
Indicates that the logical drive is currently being erased.
Predictive Spare Rebuild Ready (17)
Indicates that the logical drive is ready to perform a predictive
spare rebuild. The logical drive is in the queue for rebuild.
Rapid Parity Initialization In Progress (18)
Indicates that the logical drive is currently undergoing rapid
parity initialization (RPI). The logical drive is unavailable to the
operating system during RPI and will be made available once RPI
has completed.
Rapid Parity Initialization Pending (19)
Indicates that the logical drive is currently pending rapid
parity initialization and will be unavailable.
No Access - Encrypted - Missing Key (20)
Indicates that the logical drive is currently encrypted and cannot
be accessed because the array controller has not yet received the
encryption key from iLO nor was it found in the controller`s CSP
NVRAM.
Unencrypted to Encrypted Transformation in Progress (21)
Indicates that the logical drive is currently being transformed from
unencrypted to encrypted and the volume is online. Data will be
written unencrypted if the write is directed to an LBA range on the
logical drive that has not yet been migrated.
New Logical Drive Key Rekey in Progress (22)
Indicates that the logical drive is currently encrypted and all data
is currently being rekeyed with a new logical drive key using the
background capacity expansion transformation task. The logical drive
is online.
No Access - Encrypted with Controller Encryption Not Enabled (23)
Indicates that the logical drive is currently encrypted and cannot
be accessed because the array controller does not have encryption
enabled.
Unencrypted To Encrypted Transformation Not Started (24)
Indicates that the logical drive has received a request to transform
from unencrypted to encrypted but this process has not yet started.
The unencrypted logical drive is currently online.
New Logical Drive Key Rekey Request Received (25)
Indicates that the logical drive is encrypted and has received
a request to rekey all data with a new logical drive encryption key.
The logical drive is online.
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.3.1.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqDaLogDrvEntry
- Table
- cpqDaLogDrvTable
- Siblings
- 24
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqDaLogDrvCntlrIndex mandatory Drive Array Logical Drive Controller Index.
This maps the logical drives into their respective controllers.
Controller index `i` under the controller group owns the… | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.1 |
| cpqDaLogDrvPhyDrvIDs obsolete Drive Array Logical Drive Physical Drive IDs.
This lists the physical drive IDs which are associated with this
logical drive. These are the same IDs which can be us… | column | OctetString | .1.3.6.1.4.1.232.3.2.3.1.1.10 |
| cpqDaLogDrvCondition mandatory The Logical Drive condition.
This value represents the overall condition of this logical drive and
any associated physical drives. | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.11 |
| cpqDaLogDrvPercentRebuild mandatory Logical Drive Percent Rebuild.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value is the percent
complete o… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.3.2.3.1.1.12 |
| cpqDaLogDrvStripeSize mandatory Logical Drive Stripe Size.
This is the size of a logical drive stripe in kilobytes. | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.13 |
| cpqDaLogDrvOsName mandatory Logical Drive OS Name.
The OS name for this array logical drive. This field will be
a null (size 0) string if the agent does not support OS name. | column | OctetString | .1.3.6.1.4.1.232.3.2.3.1.1.14 |
| cpqDaLogDrvBlinkTime mandatory Logical Drive Physical Drive Blink Time Count.
The logical drive blink time variable allows the drive tray LEDs
of all physical drives in a logical drive to blink. … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.3.1.1.15 |
| cpqDaLogDrvSpareReplaceMap obsolete Logical Drive Spare To Replacement Drive Map.
This data structure contains the spare to physical drive
replacement map. The format is:
octet cont… | column | OctetString | .1.3.6.1.4.1.232.3.2.3.1.1.16 |
| cpqDaLogDrvRebuildingPhyDrv mandatory Logical Drive Physical Drive Rebuilding Index.
This is the physical drive index of the physical drive that is
currently rebuilding. If the value cannot be determin… | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.17 |
| cpqDaLogDrvMultipathAccess mandatory Logical Drive Multi-path Access.
This indicates whether all the physical disks including spares
of this logical drive have been configured to have and currently
sti… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.18 |
| cpqDaLogDrvNmbrOfParityGroups mandatory Logical Drive Number Of Parity Groups.
Indicates the number of parity groups (i.e. RAID 4/5/6 subvolumes),
that are being striped across. | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.19 |
| cpqDaLogDrvIndex mandatory Drive Array Logical Drive Index.
This logical drive number keeps track of multiple instances of
logical drives which are on the same controller. For each
controlle… | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.2 |
| cpqDaLogDrvSplitMirrorBackupLogDrv mandatory Logical Drive Split Mirror Backup Logical Drive.
Indicates if this logical drive is a backup logical drive
belonging to a split mirror.
The following… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.20 |
| cpqDaLogDrvCacheVolAccelAssocType mandatory Logical Drive Cache Volume Accelerator Association Type.
Indicates the way in which this logical drive is associated with a
cache volume accelerator group.
… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.21 |
| cpqDaLogDrvCacheVolIndex mandatory Logical Drive Cache Volume Index.
The logical drive index of the cache volume used by this logical
drive. The value of this index is the same as the logical drive … | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.22 |
| cpqDaLogDrvRPIPercentComplete mandatory Logical Drive Rapid Parity Initialization Percent Complete.
When a fault tolerant logical volume is created, parity data for
the volume must be initialized. This va… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.3.2.3.1.1.23 |
| cpqDaLogDrvSSDSmartPathStatus mandatory Logical Drive SSD Smart Path Status.
Indicates the logical drive SSD Smart Path status. An SSD Smart Path
for a logical drive can be utilized only when both the Sma… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.24 |
| cpqDaLogDrvEncryptionStatus mandatory Logical Drive Encryption Status.
Indicates the logical drive encryption status.
The following values are defined:
Other (1)
Indi… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.25 |
| cpqDaLogDrvFaultTol mandatory Logical Drive Fault Tolerance.
This shows the fault tolerance mode of the logical drive.
The following values are valid for the Logical Drive Fault
Tolerance:
… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.3 |
| cpqDaLogDrvAutoRel mandatory Array Controller Logical Drive Auto-Reliability Delay.
This value indicates how many seconds the logical drive will wait
with no requests before beginning Auto-Reli… | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.5 |
| cpqDaLogDrvRebuildBlks obsolete Logical Drive Rebuild Blocks Remaining.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value shows how many
b… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.3.1.1.6 |
| cpqDaLogDrvHasAccel mandatory Logical Drive Has Cache Module Board.
This indicates whether the logical drive has a Cache Module
board configured and enabled. The following values are valid:
… | column | Enumeration | .1.3.6.1.4.1.232.3.2.3.1.1.7 |
| cpqDaLogDrvAvailSpares obsolete Drive Array Logical Drive Available Spares.
This indicates if this logical drive has one or more spares
designated for it that are not currently in use by another d… | column | OctetString | .1.3.6.1.4.1.232.3.2.3.1.1.8 |
| cpqDaLogDrvSize mandatory Logical Drive Size.
This is the size of the logical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturer… | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.1.1.9 |