cpqDaLogDrvSprRplcCntlrExtended
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.3.3.1.2
Object
column
mandatory
Integer32
Drive Array Logical Drive Spare Replacement Controller Extended.
This value maps the spare replacement drives into their respective
controllers. This value is a logical number whose meaning is OS
dependent. The value has a direct mapping to the controller table
index such that controller `i` has spare replacement controller
extended table entry `i`.
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.3.3.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqDaLogDrvSprRplcExtAttachEntry
- Table
- cpqDaLogDrvSprRplcExtAttachTable
- Siblings
- 4
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqDaLogDrvSprRplcAttachExtIndex mandatory Drive Array Logical Drive Spare Replacment Extended Attach Index.
This index uniquely identifies a controller, logical drive, physical drive
and replacement drive c… | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.3.1.1 |
| cpqDaLogDrvSprRplcLogDrvExtended mandatory Drive Array Logical Drive Spare Replace Logical Drive Extended.
This logical drive number keeps track of multiple instances of
logical drives which are on the same … | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.3.1.3 |
| cpqDaLogDrvSprRplcReplacedPhysDrvExtended mandatory Drive Array Logical Drive Spare Replace Replaced Physical
Drive Extended.
This is the replaced drive physical drive number. | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.3.1.4 |
| cpqDaLogDrvSprRplcSparePhysDrvExtended mandatory Drive Array Logical Drive Spare Replace Spare Physical
Drive Extended.
This is the replacement spare physical drive number. | column | Integer32 | .1.3.6.1.4.1.232.3.2.3.3.1.5 |