cpqDaAccelBattery

CPQIDA-MIB · .1.3.6.1.4.1.232.3.2.2.2.1.6

Object

column mandatory Enumeration
Cache Module Board Backup Power Status.
              
This monitors the status of each backup power source on the board.  
The backup power source can only recharge when the system has 
power applied. The type of backup power source used is indicated 
by cpqDaAccelBackupPowerSource.
              
The following values are valid:
              
Other (1)
  Indicates that the instrument agent does not recognize
  backup power status.  You may need to update your software.
              
Ok (2)
  The backup power source is fully charged.
              
Recharging (3)
  The array controller has one or more cache module backup power
  sources that are recharging.  Cache module operations such as 
  Battery/Flash Backed Write Cache, Expansion, Extension and Migration
  are temporarily suspended until the backup power source is fully 
  charged.  Cache module operations will automatically resume
  when charging is complete.
              
Failed (4)
  The battery pack is below the sufficient voltage level and
  has not recharged in 36 hours.  Your Cache Module board
  needs to be serviced.
              
Degraded (5)
  The battery is still operating, however, one of the batteries
  in the pack has failed to recharge properly.  Your Cache
  Module board should be serviced as soon as possible.
              
NotPresent (6)
  A backup power source is not present on the cache module board.
  Some controllers do not have backup power sources.
                
Capacitor Failed (7)
  The flash backed cache module capacitor is below the sufficient 
  voltage level and has not recharged in 10 minutes.  Your Cache 
  Module board needs to be serviced.

Context

MIB
CPQIDA-MIB
OID
.1.3.6.1.4.1.232.3.2.2.2.1.6
Type
column
Access
readonly
Status
mandatory
Parent
cpqDaAccelEntry
Table
cpqDaAccelTable
Siblings
19

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects