smResetToDefault
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9
Object
column
mandatory
r/w
Enumeration
For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object.
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- smPowerRestartEntry
- Table
- smPowerRestartTable
- Siblings
- 15
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | execute |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| smPowerRestartIndex mandatory Switch module power restart index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1 |
| smRestartAndRunStdDiag mandatory To power cycle the selected module(s) and then run the standard diagnostic
test package.
NOTE: Value returned for the GET command is meaningless for this MIB object. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10 |
| smRestartAndRunExtDiag mandatory To power cycle the selected module(s) and then run the extended diagnostic
test package. This option is not supported on all I/O modules.
NOTE: Value returned for t… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11 |
| smRestartAndRunFullDiag mandatory To power cycle the selected module(s) and then run the full diagnostic test
package. The full diagnostic test package may take over 5 minutes to run.
This option is not supported … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 |
| smPowerOnRestartDelay mandatory Restart delay (in seconds) when power is applied to a switch module. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.15 |
| smPowerRestartId mandatory The switch module numeric identifier. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2 |
| smSwitchWidth mandatory Switch module width. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21 |
| smManufacturingID mandatory Switch module hardware VPD manufacturing ID. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22 |
| smStackingModeState mandatory The Stacking Mode Status for the switch module.
standby - I/O module has stacking capability but is not part of a stack.
member - I/O module has stacking capability and is part of… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23 |
| smStackingModeInfo mandatory A string containing a text description about the details of which functions are
protected for a switch module when it is in Stacking Mode as Master or Member.
The possible functio… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24 |
| smSwitchExists mandatory Indicates whether the switch module specified exists or not. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3 |
| smMACAddress mandatory Switch module MAC address.
For IOMs which are members of a stack, this field is not applicable and should be disregarded. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5 |
| smIPAddress mandatory The switch module current IP address.
If the switch module is participating in the Stacking Mode
and IP Configuration is protected, then the stack management
IP address is display… | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6 |
| switchModulePowerOnOff mandatory I/O Module power on or power off. If powering on a currently
powered off I/O Module, then the I/O Module will execute a POST.
The results of this POST will need to be retrieved u… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7 |
| smReset mandatory For the case where the switch module is currently powered on, this command
will effectively power off and then power on the switch module indicated and
cause it to run its POST te… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8 |