pd1BayNumber
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2
Object
column
mandatory
OctetString
Power Domain 1 Table Bay Number. The following Bay Number IDs are used: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), fanPackBay5(7), fanPackBay6(8), chassisfanBay1(9), chassisfanBay2(10), chassisfanBay3(11), chassisfanBay4(12), chassisfanBay5(13), chassisfanBay6(14), chassisfanBay7(15), chassisfanBay8(16), chassisfanBay9(17), chassisfanBay10(18), managementModuleBay1(19), managementModuleBay2(20), ioModuleBay1(21), ioModuleBay2(22), ioModuleBay3(23), ioModuleBay4(24), serverBladeBay1(25), serverBladeBay2(26), serverBladeBay3(27), serverBladeBay4(28), serverBladeBay5(29), serverBladeBay6(30), serverBladeBay7(31), serverBladeBay8(32), serverBladeBay9(33), serverBladeBay10(34), serverBladeBay11(35), serverBladeBay12(36), serverBladeBay13(37), serverBladeBay14(38), notApplicable(39)
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- powerDomain1Entry
- Table
- powerDomain1Table
- Siblings
- 13
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pd1Index mandatory Power Domain 1 Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 |
| pd1ModuleCPUDutyCycles mandatory Power Domain 1 Table Module CPUs Duty Cycles applies to blade
servers only. It displays the duty cycle for each CPU on the blade
as a percentage. Note that some blades do not re… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 |
| pd1ModuleThrottle mandatory Power Domain 1 Table Module Throttle indicates whether the
server blade may be allowed to throttle or not. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 |
| pd1ModulePowerCapabilities mandatory Power Domain 1 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 |
| pd1ModuleMeasuredOrStatic mandatory Power Domain 1 Table Module Measured Or Static. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 |
| pd1TopologyPath mandatory The topology path for the component in this table. The chassis and each
installed component is represented by a hardware topology tree, where
each node in the tree represents a co… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.14 |
| pd1BladePrimarySlot mandatory Power Domain 1 Table Blade Primary Slot can be useful
when a server blade spans multiple slots (e.g. double wide or
triple wide). For example if the blade is double wide and
is i… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 |
| pd1ModuleStatus mandatory Power Domain 1 Table Module Throttle Status. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 |
| pd1ModuleName mandatory Power Domain 1 Table Module Name. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 |
| pd1ModuleState mandatory Power Domain 1 Table Module State. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 |
| pd1ModuleAllocatedPowerCurrent mandatory Power Domain 1 Table Allocated Power Current indicates the current power
allocation for the module in Watts.
NOTE: When a server blade spans multiple slots (e.g. do… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 |
| pd1ModuleAllocatedPowerMax mandatory Power Domain 1 Table Allocated Power Max indicates the maximum power
allocation for the module in Watts. It is indicative of the maximum
amount of power the module will consume i… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 |
| pd1ModuleAllocatedPowerMin mandatory Power Domain 1 Table Allocated Power Min indicates the minumum power
allocation for the module in Watts. It is indicative of the minumum
power consumption of the component in the… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 |