cwrArqReset
CISCO-WIRELESS-IF-MIB ·
.1.3.6.1.4.1.9.9.136.1.4.1.1.8
Object
This object when set to true will force the PHY quality parameters to be reset from the cwrRadioPhyTable. Reading this object will always return false. This is useful when arbitrary changes to the ARQ parameters have to be reset to known consistent valid values.
Context
- MIB
- CISCO-WIRELESS-IF-MIB
- OID
.1.3.6.1.4.1.9.9.136.1.4.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cwrPhyQualityEntry
Syntax
SNMPv2-TCTruthValue
Values & Constraints