cSmeClusterMembersEntry
CISCO-SME-MIB ·
.1.3.6.1.4.1.9.9.632.1.1.2.1
Object
row
A conceptual row in the cSmeClusterMembersTable. Each row represents a member device within a specified SME Cluster.
Context
- MIB
- CISCO-SME-MIB
- OID
.1.3.6.1.4.1.9.9.632.1.1.2.1- Type
- row
- Status
- current
- Parent
- cSmeClusterMembersTable
- Table
- cSmeClusterMembersTable
- Children
- 7
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cSmeMemberInetAddrType The type of Internet address of a cluster member within
a specified SME cluster. The Internet address of this
device is specified by the value of the corresponding
instance of cSm… | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.9.9.632.1.1.2.1.1 |
| cSmeMemberInetAddr The Internet address of the cluster member device
within a specified SME cluster.
The type of this Internet address is determined
by the value of the corresponding instance of
cS… | column | OctetString | .1.3.6.1.4.1.9.9.632.1.1.2.1.2 |
| cSmeFabric Refers to the name of physical fibre channel fabric in the
SAN. A typical SAN deployment consists of a dual fabric
topology which corresponds to two physical fabrics.
In such a … | column | OctetString | .1.3.6.1.4.1.9.9.632.1.1.2.1.3 |
| cSmeIsMemberLocal Identifies if the device is a local or remote member of
this cluster.
'true' means this device is a local device.
'false' means this device is a remote device. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.632.1.1.2.1.4 |
| cSmeMemberIsMaster Indicates if this device is currently the master of
the SME cluster.
The value 'true' means this device is the master.
The value 'false' means this device is not th… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.632.1.1.2.1.5 |
| cSmeClusterMemberStorageType This object specifies the storage type for this conceptual
row. | column | SNMPv2-TCStorageType | .1.3.6.1.4.1.9.9.632.1.1.2.1.6 |
| cSmeClusterMemberRowStatus The status of this conceptual row.
There is no restriction on the value of other columns
before a newly created row can be made active.
When a cluste… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9.9.632.1.1.2.1.7 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| cSmeClusterId Globally unique index that identifies a SME cluster.
This index must be generated in such a way that the
same value is never reused even after cluster has been
deleted. | column | CiscoSmeClusterIndex | .1.3.6.1.4.1.9.9.632.1.1.1.1.1 |
| cSmeMemberInetAddrType The type of Internet address of a cluster member within
a specified SME cluster. The Internet address of this
device is specified by the value of the corresponding
instance of cSm… | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.9.9.632.1.1.2.1.1 |
| cSmeMemberInetAddr The Internet address of the cluster member device
within a specified SME cluster.
The type of this Internet address is determined
by the value of the corresponding instance of
cS… | column | OctetString | .1.3.6.1.4.1.9.9.632.1.1.2.1.2 |