cnsSelInpSrcMSW
CISCO-NETSYNC-MIB ·
.1.3.6.1.4.1.9.9.761.1.1.2.1.8
Object
column
SNMPv2-TCTruthValue
This object indicates the manual switching flag. The 'true' value indicates the currently selected clock source is a result of the manual switch command. The command allows a user to select a synchronization source assuming it is enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode. Furthermore, in QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL.
Context
- MIB
- CISCO-NETSYNC-MIB
- OID
.1.3.6.1.4.1.9.9.761.1.1.2.1.8- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cnsSelectedInputSourceEntry
- Table
- cnsSelectedInputSourceTable
- Siblings
- 7
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsSelInpSrcNetsyncIndex An index that uniquely represents an entry in
this table. This index is assigned arbitrarily
by the clock selection process and may not be persistent
across reboots. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.2.1.1 |
| cnsSelInpSrcName This object indicates the name of the
selected T0 clock. | column | OctetString | .1.3.6.1.4.1.9.9.761.1.1.2.1.2 |
| cnsSelInpSrcIntfType This object indicates the type of the
selected T0 clock. | column | CiscoNetsyncIfType | .1.3.6.1.4.1.9.9.761.1.1.2.1.3 |
| cnsSelInpSrcQualityLevel This object indicates the selected T0 clock
source's effective quality level, which
is the derived clock quality based on the three factors:
(a) Received quality level.
(b) Conf… | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.2.1.4 |
| cnsSelInpSrcPriority This object indicates the configured
priority of the selected T0 clock.
A smaller value represents a higher priority. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.2.1.5 |
| cnsSelInpSrcTimestamp This object indicates the timestamp of
the T0 clock source being selected by
the G.781 clock selection process. | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.9.9.761.1.1.2.1.6 |
| cnsSelInpSrcFSW This object indicates the forced switching flag. Forced
switching, as described in G.781, is used to override the
currently selected synchronization source.
The 'tr… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.2.1.7 |