cnsSelectedInputSourceEntry
CISCO-NETSYNC-MIB ·
.1.3.6.1.4.1.9.9.761.1.1.2.1
Object
row
An entry is created in the table when the G.781 clock selection process has successfully selected a T0 clock source. The entry shall remain during the time the G.781 clock selection process remains enabled.
Context
- MIB
- CISCO-NETSYNC-MIB
- OID
.1.3.6.1.4.1.9.9.761.1.1.2.1- Type
- row
- Status
- current
- Parent
- cnsSelectedInputSourceTable
- Table
- cnsSelectedInputSourceTable
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsSelInpSrcNetsyncIndex An index that uniquely represents an entry in
this table. This index is assigned arbitrarily
by the clock selection process and may not be persistent
across reboots. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.2.1.1 |
| cnsSelInpSrcName This object indicates the name of the
selected T0 clock. | column | OctetString | .1.3.6.1.4.1.9.9.761.1.1.2.1.2 |
| cnsSelInpSrcIntfType This object indicates the type of the
selected T0 clock. | column | CiscoNetsyncIfType | .1.3.6.1.4.1.9.9.761.1.1.2.1.3 |
| cnsSelInpSrcQualityLevel This object indicates the selected T0 clock
source's effective quality level, which
is the derived clock quality based on the three factors:
(a) Received quality level.
(b) Conf… | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.2.1.4 |
| cnsSelInpSrcPriority This object indicates the configured
priority of the selected T0 clock.
A smaller value represents a higher priority. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.2.1.5 |
| cnsSelInpSrcTimestamp This object indicates the timestamp of
the T0 clock source being selected by
the G.781 clock selection process. | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.9.9.761.1.1.2.1.6 |
| cnsSelInpSrcFSW This object indicates the forced switching flag. Forced
switching, as described in G.781, is used to override the
currently selected synchronization source.
The 'tr… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.2.1.7 |
| cnsSelInpSrcMSW This object indicates the manual switching flag.
The 'true' value indicates the currently selected clock source
is a result of the manual switch command. The command allows
a user… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.2.1.8 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsSelInpSrcNetsyncIndex An index that uniquely represents an entry in
this table. This index is assigned arbitrarily
by the clock selection process and may not be persistent
across reboots. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.2.1.1 |