cmPhyIfClientSubrateLock
CISCO-METRO-PHY-MIB ·
.1.3.6.1.4.1.9.10.69.1.1.1.1.16
Object
This object allows the management client to lock the
subrate bandwidth on an interface, by writing a value of
'true' to this object. A 'false' value would disable the
bandwidth lock. If the clients bandwidth is locked then
this client will not share its bandwidth with the other
clients on the same oversubscribed trunk.
SubrateLock does not apply when the value of
cmPhyIfClientSubrate is zero.
Context
- MIB
- CISCO-METRO-PHY-MIB
- OID
.1.3.6.1.4.1.9.10.69.1.1.1.1.16- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cmPhyIfEntry
- Table
- cmPhyIfTable
- Siblings
- 15
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cmPhyIfMode This object allows the management client to configure
the mode of operation for the client interface modules.
When in 2R mode, there is no protocol type, clock rate… | column | Enumeration | .1.3.6.1.4.1.9.10.69.1.1.1.1.1 |
| cmPhyIfAutoNegotiation This object allows the management client to enable
auto negotiation signaling on the client side interface,
by writing a 'true' value to this object. A 'false'
value would disable… | column | TriValue | .1.3.6.1.4.1.9.10.69.1.1.1.1.10 |
| cmPhyIfTransType This object is used to identify the physical layer medium used
for carrying data. For non-relevant interfaces, this value is
'unknown'. | column | TransmissionType | .1.3.6.1.4.1.9.10.69.1.1.1.1.11 |
| cmPhyIfRate This object is used to specify the rate of the interface.
The value of 'unknown' implies that this object does not
apply to this interface. | column | CmRateType | .1.3.6.1.4.1.9.10.69.1.1.1.1.12 |
| cmPhyIfNegotiatedRate This object is used to identify the current rate of the
interface after the auto negotation. This object is valid
only if the object cmPhyIfRate is configured as 'auto'. | column | CmNegotiatedRateType | .1.3.6.1.4.1.9.10.69.1.1.1.1.13 |
| cmPhyIfOverSubscription Oversubscription allows the user to carry multiple clients
over the trunk to efficiently utilize the trunk bandwidth.
This object allows the management client to en… | column | TriValue | .1.3.6.1.4.1.9.10.69.1.1.1.1.14 |
| cmPhyIfClientSubrate This object allows the management client to specify the
subrate bandwidth of the oversubscribed trunk which carries
this client.
A value of 0 implies that this obj… | column | mega-bytes-per-second Unsigned32 | .1.3.6.1.4.1.9.10.69.1.1.1.1.15 |
| cmPhyIfProtocol This object is used to specify the protocol of the data
carried over the client side interface.
This object applies to linecards which support a variety of
protoco… | column | ProtocolType | .1.3.6.1.4.1.9.10.69.1.1.1.1.2 |
| cmPhyIfClockRate This object allows the management client to set the
clock rate across the client side interface.
Due to hardware limitations, all values may not be supported.
The d… | column | kHz Integer32 | .1.3.6.1.4.1.9.10.69.1.1.1.1.3 |
| cmPhyIfMonitor This object allows the management client to enable
monitoring of the error counters on an interface,
by writing a value of 'true' to this object. To bypass
the monitoring hardwar… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.69.1.1.1.1.4 |
| cmPhyIfLoopback This object allows the management client to configure
loopback for the client side or trunk side interfaces.
'noLoop' - No Loopback present.
'diagnosticLoop… | column | Enumeration | .1.3.6.1.4.1.9.10.69.1.1.1.1.5 |
| cmPhyIfOFC This object allows the management client to enable
OFC(Open Fibre Control) safety protocol for the client
side interfaces, by writing a 'true' value to
this object. A 'false' val… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.69.1.1.1.1.6 |
| cmPhyIfLaserSafetyControl deprecated This object allows the management client to enable
laser safety control feature on the trunk side interfaces
by writing a true value to this object. If laser safety
control is ena… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.69.1.1.1.1.7 |
| cmPhyIfForwardLaserControl deprecated This object allows the management client to enable
forward laser control on the client or trunk side interfaces
by writing a true value to this object. If forward laser
control i… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.69.1.1.1.1.8 |
| cmPhyIfTxBufferSize This object applies when circuit emulation of the client
protocol is used. It allows the management client to
configure the size of the transmit buffer on the client
port. A value… | column | bytes Unsigned32 | .1.3.6.1.4.1.9.10.69.1.1.1.1.9 |