cmPhyHCTxEncapFarEndPktErrors
CISCO-METRO-PHY-MIB ·
.1.3.6.1.4.1.9.10.69.1.2.1.1.13
Object
column
SNMPv2-SMICounter64
This object represents the counter associated with ESCON
ingress error indications from the far end of
an Ethernet network, where an ESCON stream is encapsulated in
Ethernet packets. This counter is incremented whenever
an ESCON packet or control character has 8b/10b code
violations or running disparity errors in the ingress
direction at the far end of the Ethernet network.
This object has a valid value only for ESCON interfaces where
Ethernet encapsulation is performed.
This is a High Capacity (64 bit) version of the
cmPhyTxEncapFarEndPktErrors counter.
Context
- MIB
- CISCO-METRO-PHY-MIB
- OID
.1.3.6.1.4.1.9.10.69.1.2.1.1.13- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cmPhyStatisticsEntry
- Table
- cmPhyStatisticsTable
- Siblings
- 12
Syntax
SNMPv2-SMICounter64
- Source
- SNMPv2-SMICounter64
- Base type
Unsigned64
Values & Constraints
Type Constraints
range: 0..18446744073709551615
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cmPhyRxPower deprecated This object gives the optical power level received
on the trunk side interface.
The actual value of the power level received on
the interface is the value of this … | column | dBm Integer32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.1 |
| cmPhyHCRxCRC This object represents the counter associated with
CRC errors. This object has a valid value only for
interfaces that provide CRC error monitoring.
This is a Hig… | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.9.10.69.1.2.1.1.10 |
| cmPhyTxEncapFarEndPktErrors This object represents the lower word value of the counter
associated with ingress error indications from the far end of
an Ethernet network, where an ESCON stream is encapsulated… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.11 |
| cmPhyTxEncapFarEndPktErrOverflow This object represents the higher word value of the counter
associated with ingress error indications from the far end of
an Ethernet network, where an ESCON stream is encapsulate… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.12 |
| cmPhyRxCVRD This object represents the lower word value of the
counter associated with the
number of code violations and running disparity errors
encountered, in the receive direction.
… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.2 |
| cmPhyRxCVRDOverflow This object represents the high word value of the
counter associated with the
number of code violations and running disparity errors
encountered, in the receive direction.
… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.3 |
| cmPhyHCRxCVRD This object represents the counter associated with the
number of code violations and running disparity errors
encountered, in the receive direction.
This is a High … | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.9.10.69.1.2.1.1.4 |
| cmPhyRxHEC deprecated This object represents the lower word value of the
counter associated with the
number of CDL HEC errors encountered, in the receive
direction.
This object has a va… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.5 |
| cmPhyRxHECOverflow deprecated This object represents the high word value of the
counter associated with the number of CDL
HEC errors encountered, in the receive direction.
This object has a val… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.6 |
| cmPhyHCRxHEC deprecated This object represents the counter associated with the
number of CDL HEC errors encountered, in the receive
direction.
This object has a valid value only if the medium
type is gig… | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.9.10.69.1.2.1.1.7 |
| cmPhyRxCRC This object represents the lower word value of the
counter associated with CRC errors.
This object has a valid value only for interfaces that
provide CRC error monitoring.
… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.8 |
| cmPhyRxCRCOverflow This object represents the higher word value of the
counter associated with CRC errors.
This object has a valid value only for interfaces that
provide CRC error monitoring.
… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.10.69.1.2.1.1.9 |