cdxCmtsCmOnOffTrapInterval

CISCO-DOCS-EXT-MIB · .1.3.6.1.4.1.9.9.116.1.3.3.1.2

Object

column r/w seconds Integer32
The interval for cdxCmtsCmOnOffNotification sent by CMTS for
one online/offline state change if cdxCmtsCmOnOffTrapEnable 
is true. 
              
If there are more than one state changes to online/offline 
for a cable modem during this interval, only one 
cdxCmtsCmOnOffNotification is sent by CMTS for the first 
state change to online and one cdxCmtsCmOnOffNotification 
for the first state changing to offline if 
cdxCmtsCmOnOffTrapEnable is true.
              
This is to avoid too many notifications sent for a cable 
modem online/offline state changes during a short period
of time. 
              
If the value is 0, then cdxCmtsCmOnOffNotification will be 
sent for every state changes to online/offline for a cable 
modem if cdxCmtsCmOnOffTrapEnable is true.  
              
If cdxCmtsCmOnOffTrapEnable value changes from true to false 
or from false to true, this value will remain no change as 
before. 
              
The default value is 600 seconds.

Context

MIB
CISCO-DOCS-EXT-MIB
OID
.1.3.6.1.4.1.9.9.116.1.3.3.1.2
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
cdxCmtsMacExtEntry
Table
cdxCmtsMacExtTable
Siblings
7

Syntax

seconds Integer32

Values & Constraints

Object Constraints
range: 0-86400