cbSingleBitErrorInsert
CISCO-BERT-MIB ·
.1.3.6.1.4.1.9.9.185.1.1.1.1.7
Object
column
r/w
Enumeration
This object is used for inserting single bit error in the
transmitted BERT pattern.
The possible values are:
noError(1) : do not insert single bit errors
insertError(2) : insert single bit errors.
Context
- MIB
- CISCO-BERT-MIB
- OID
.1.3.6.1.4.1.9.9.185.1.1.1.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cbConfEntry
- Table
- cbConfTable
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | noError |
2 | insertError |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cbTestPattern The BERT pattern to be sent and expected to be received.
An implementation may choose to support only selected patterns.
In some implementations, this object can not be modified w… | column | BertPatterns | .1.3.6.1.4.1.9.9.185.1.1.1.1.1 |
| cbOperStatus This object shows the status of BERT in the shelf.
The values for this object are valid only when
cbRowStatus contains active(1).
Possible values for this object:
… | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.10 |
| cbFailedReason This object contains the reason for the BERT failure.
This object gives the additional information when
cbOperStatus is set to bertFailed(6).
The possible val… | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.11 |
| cbStartDateAndTime The Date and Time when the last BERT testing is started
on the interface. This object is valid only when
cbRowStatus is active(1). | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.185.1.1.1.1.12 |
| cbDS0DPCodeIteration Valid only with cbLoopbackCode = latchDS0Drop.
DSP-OP devices can be cross connected in the central
office in a daisy chain. By this, the user has
capability to put any of the d… | column | Integer32 | .1.3.6.1.4.1.9.9.185.1.1.1.1.13 |
| cbRowStatus The status of this conceptual row. This object is used for
create or modify or deleting an entry from this table.
To create a row in this table, a manager must set… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9.9.185.1.1.1.1.14 |
| cbDs0BitMap This object is only used IF the interface type is DS1
(ifType is 18 on ifTable).
This object is used to indicate which DS0 is involved
on the BERT.
The defualt value (DEFVAL) is v… | column | Bits | .1.3.6.1.4.1.9.9.185.1.1.1.1.15 |
| cbUserPattern The object used for configuring the user defined pattern
for BERT. This is the fixed repeating BERT pattern sent
and expected to be received when the cbTestPattern object is
set … | column | OctetString | .1.3.6.1.4.1.9.9.185.1.1.1.1.2 |
| cbBertTxPatternInv This controls inversion of the transmit BERT pattern.
Possible values are :
notInverted(1): Pattern is transmitted normally.
inverted(2): Each Mark is replaced by … | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.3 |
| cbBertRxPatternInv This controls inversion of the received BERT pattern.
Possible values are :
notInverted(1) : Pattern received is not inverted.
inverted(2) : each Mark is repla… | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.4 |
| cbLoopback This object specifies the type of loopback established.
Possible values are:
farEndLineLoopback(1): This loopback occurs at the CPE upon
receiving a special code f… | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.5 |
| cbLoopbackCode This object specifies the type of the end device and
the type of loopback code used.
Latching Loopback: Latching Loopback is appropriate with
64 kbit/s DS0-A rate. … | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.6 |
| cbErrorInsertionRate This object is used for injecting continuous errors into
transmitted BERT pattern. The errors are inserted in a BERT
pattern sent, in order to do sanity check on receive interf… | column | Enumeration | .1.3.6.1.4.1.9.9.185.1.1.1.1.8 |
| cbDuration This object specifies the duration for which BERT is
to be run. | column | seconds Integer32 | .1.3.6.1.4.1.9.9.185.1.1.1.1.9 |