cApsConfigSwitchoverEnableInterval

CISCO-APS-EXT-MIB · .1.3.6.1.4.1.9.10.72.1.2.1.5

Object

column r/w seconds Integer32
This object specifies the value of the timer to control
the minimum interval between switchovers. After a switchover,
APS is re-enabled only after this amount of time has elapsed,
in order to prevent quick successive switchovers.

Context

MIB
CISCO-APS-EXT-MIB
OID
.1.3.6.1.4.1.9.10.72.1.2.1.5
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
cApsConfigExtEntry
Table
cApsConfigExtTable
Siblings
11

Syntax

seconds Integer32

Values & Constraints

Object Constraints
range: 1-120

Related Objects

Sibling Objects