cApsConfigMinSearchUpInterval

CISCO-APS-EXT-MIB · .1.3.6.1.4.1.9.10.72.1.2.1.3

Object

column r/w Integer32
This object is instantiated only when the standby interface
is not monitored. If both interfaces go down and the standby
interface is not monitored, successive switchovers may be used
in order to search for an interface that is up.
              
This object specifies the minimum time interval between
switchovers when both interfaces go down. A backoff algorithm
should be used to increase the time interval between
successive switchovers.

Context

MIB
CISCO-APS-EXT-MIB
OID
.1.3.6.1.4.1.9.10.72.1.2.1.3
Type
column
Access
readwrite
Status
current
Parent
cApsConfigExtEntry
Table
cApsConfigExtTable
Siblings
11

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-120