cienaCesBenchmarkEntityEntryOperEnabled
CIENA-CES-BENCHMARK-MIB ·
.1.3.6.1.4.1.1271.2.1.39.1.1.2.1.14
Object
column
SNMPv2-TCTruthValue
Entity operational enable/disable. An entity is operationally enabled when the feature is enabled, the entity is enabled and at least one test instance associated with that entity is enabled (reflector) or running (generator)
Context
- MIB
- CIENA-CES-BENCHMARK-MIB
- OID
.1.3.6.1.4.1.1271.2.1.39.1.1.2.1.14- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cienaCesBenchmarkEntityEntry
- Table
- cienaCesBenchmarkEntityTable
- Siblings
- 23
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cienaCesBenchmarkEntityEntryId Entity unique ID | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.1 |
| cienaCesBenchmarkEntityEntryReflectionLevel For reflector entities, this indicates the minimum reflection
level required. If test traffic is going over an ethernet L2
cloud, l2-only is fine. But if the test traffic is going… | column | Enumeration | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.10 |
| cienaCesBenchmarkEntityEntryGeneratorHFrameSize Maximum frame size that should be generated by the generator
device. This H frame size should to leave enough room for
extra encapsulation bytes that will be pushed onto the
pack… | column | Integer32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.11 |
| cienaCesBenchmarkEntityEntryMaxConfigTestInstances Maximum number of test instances that can
be configured on this entity. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.12 |
| cienaCesBenchmarkEntityEntryMaxSimultaneousTestInstances Maximum number of test instances that can
be enabled (reflector) or running (generator)
on this entity, given the availability of
hw sessions. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.13 |
| cienaCesBenchmarkEntityEntryNumTestInstancesConfigured Number of test instances currently configured
on this entity. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.15 |
| cienaCesBenchmarkEntityEntryNumTestInstancesEnabled Number of test instances currently enabled. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.16 |
| cienaCesBenchmarkEntityEntryGenNumTestInstancesRunning Number of test instances currently running. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.17 |
| cienaCesBenchmarkEntityEntryBwAvailable Bandwidth available for test traffic if
a reflector. Bandwidth remaining for other
test instances to be started if a generator. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.18 |
| cienaCesBenchmarkEntityEntryGenBwUsedByRunningTests Bandwidth currently used by test instances
currently running, in Mbps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.19 |
| cienaCesBenchmarkEntityEntryName Name of the benchmark entity as entered when created. | column | OctetString | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.2 |
| cienaCesBenchmarkEntityEntryAvailableHwSessions Maximum number of simultaneous hardware sessions available
on this platform. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.20 |
| cienaCesBenchmarkEntityEntryAllocatedHwSessions The number of allocated hardware sessions | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.21 |
| cienaCesBenchmarkEntityEntryRowStatus Used to manage the creation and deletion of the
conceptual rows in this table. To create a row in
this table, set this object to 'createAndGo'.
To delete a row in this table, set… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.22 |
| cienaCesBenchmarkEntityEntryClearStats Set to true to clear all global fpga counters for the given entity.
Clear is only allowed for a reflector if no test instances are
enabled, and for a generator if no test instance… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.23 |
| cienaCesBenchmarkEntityEntryReflectorMacValidation This attribute is only valid for the reflector entity and indicates
whether the reflector verifies that the destination MAC of the test
frames matches the MAC address associated w… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.24 |
| cienaCesBenchmarkEntityEntryRole Entity role | column | Enumeration | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.3 |
| cienaCesBenchmarkEntityEntryPortId Entity port under test | column | Integer32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.4 |
| cienaCesBenchmarkEntityEntryMode Entity mode | column | Enumeration | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.5 |
| cienaCesBenchmarkEntityEntryAdminState Entity admin state. | column | CienaCesBenchmarkAdminState | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.6 |
| cienaCesBenchmarkEntityEntryLocalMac The FPGA internal test port assigned mac address. | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.7 |
| cienaCesBenchmarkEntityEntrySlotId The slot Id of the line module associated
with this entity. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.8 |
| cienaCesBenchmarkEntityEntryReflectorVendorType Indicator as to what type of equipment is generating the
test traffic on the remote end. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.39.1.1.2.1.9 |