gnGenDrawerXDeviceIDUStatus
CERAGON-MIB ·
.1.3.6.1.4.1.2281.2.1.27.1.7
Object
column
mandatory
OctetString
IDU status reported with this parameter. Bit1 is MSB.
The bit is set when a fault occurs. The bit is
cleared when the fault clears.
bit 1 = Power status
bit 2 = Cable open status
bit 3 = Cable short status
bit 4 = Modem Lock status
bit 5 = Temperature status
bit 6 = No signal from ODU (Phos only)
bit 7 = loopback status
bit 8 = External alarm 1 status
bit 9 = External alarm 2 status
bit 10 = External alarm 3 status
bit 11 = External alarm 4 status
bit 12 = External alarm 5 status
bit 13 = External alarm 6 status
bit 14 = External alarm 7 status
bit 15 = External alarm 8 status
bit 16 = Remote connectivity status.
bit 17 = Inner communication status.
bit 18 = Link ID mismatch status.
bit 19 = Configuration mismatch status.
bit 20 = Shelf Id mismatch status (Phos only).
bit 21 = General HW failure.
bit 22 = No power to MUX board.
bit 23 = No power to MODEM board.
bit 24 = IDC disk firmware cinfiguration mismatch.
bit 25 = Modem configuration file.
bit 26 = Wayside channel E1/T1 LOS
bit 27 = loopback on Wayside channel
Context
- MIB
- CERAGON-MIB
- OID
.1.3.6.1.4.1.2281.2.1.27.1.7- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- gnGenDrawerXEntry
- Table
- gnGenDrawerXTable
- Siblings
- 6
Syntax
OctetString
Values & Constraints
Object Constraints
range: 4-4
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| gnGenDrawerXId mandatory This value indicates the drawer's id | column | Enumeration | .1.3.6.1.4.1.2281.2.1.27.1.1 |
| gnGenDrawerXName mandatory This value indicates the drawer's name | column | OctetString | .1.3.6.1.4.1.2281.2.1.27.1.2 |
| gnGenDrawerXSlot1Status mandatory notExist - board not exist.
powerOff - board inserted and power off.
powerOn - board inserted and power on.
dbReady - board is power on and DB ready. | column | Enumeration | .1.3.6.1.4.1.2281.2.1.27.1.3 |
| gnGenDrawerXSlot2Status mandatory notExist - board not exist.
powerOff - board inserted and power off.
powerOn - board inserted and power on.
dbReady - board is power on and DB ready. | column | Enumeration | .1.3.6.1.4.1.2281.2.1.27.1.4 |
| gnGenDrawerXDeviceLeds mandatory The status of the IDU front panel LEDs. For the management station use. | column | OctetString | .1.3.6.1.4.1.2281.2.1.27.1.5 |
| gnGenDrawerXInternalCommunication mandatory The status of internal communication problem
bit 1 = 1: between main CPU and ODU CPU.
bit 2 = 1: between main CPU and MUX CPU.
bit 3 = 1: between master main CPU and slave main CP… | column | OctetString | .1.3.6.1.4.1.2281.2.1.27.1.6 |