maxModulation

CAMBIUM-PTP800-MIB · .1.3.6.1.4.1.17713.8.10.8

Object

scalar Enumeration
When adaptive modulation is enabled, PTP 800 will adapt 
the modulation mode between a minimum and maximum 
modulation mode. Depending on the region, minimum and 
maximum modulation modes will be either derived from the 
radio license, e.g. FCC and Industry Canada, or will be 
user adjustable, e.g. ETSI. In general, a modulation mode 
is defined by two aspects, a modulation and a code rate. 
This integer attribute identifies the modulation aspect 
of the maximum modulation mode. For example, if the 
maximum modulation mode is 256QAM 0.91, this attribute 
will be set to a value of 6 which identifies a modulation 
of 256QAM.

Context

MIB
CAMBIUM-PTP800-MIB
OID
.1.3.6.1.4.1.17713.8.10.8
Type
scalar
Access
readonly
Status
current
Parent
phyControl
Siblings
4

Syntax

Enumeration

Values & Constraints

Enumerated Values
0modQPSK
1mod8PSK
2mod16QAM
3mod32QAM
4mod64QAM
5mod128QAM
6mod256QAM

Related Objects