neHTAutoShutdown
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.1.15
Object
scalar
r/w
Enumeration
A system wide setting that specifies whether the circuit pack pack high temperature automatic shutdown (HTAS) is enabled. When enabled, the circuit packs which support the HTAS feature will be automatically powered down if the shutdown temperature threshold for that circuit pack is exceeded. There will be alarms indicating that the shutdown has occurred. The default setting is enabled.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.1.15- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- networkElement
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Object Constraints
range: 1-64
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| neSWVersion The software version that is active on the NE currently. | scalar | OctetString | .1.3.6.1.4.1.18070.2.2.1.1.1 |
| neAutoProv A setting that specifies if automatic provisioning of
equipment and facilities is enabled. If automatic provisioning
is enabled, this object indicates the default administration
s… | scalar | Enumeration | .1.3.6.1.4.1.18070.2.2.1.1.10 |
| neAutoDeProv obsolete The time delay after a physical shelf or circuit pack is
removed from the NE before the provisioned entities that are
supported by the removed equipment are automatically
deprovis… | scalar | BTI-TC-MIBHoursAndMinutes | .1.3.6.1.4.1.18070.2.2.1.1.11 |
| neAutoEnabledTimer The system wide default auto-enable timer value. This timer
specifies a time delay after a provisioned facility in the
auto-enabled state is cleared of all alarms before the state… | scalar | BTI-TC-MIBHoursAndMinutes | .1.3.6.1.4.1.18070.2.2.1.1.12 |
| ntpClient | node | - | .1.3.6.1.4.1.18070.2.2.1.1.13 |
| neFPDetect A setting that indicates whether the system should report pack
missing alarms. | scalar | Enumeration | .1.3.6.1.4.1.18070.2.2.1.1.14 |
| neNum This is a unique network element number used to identify the
network element and to differentiate it from other NEs in the
management domain. | scalar | Integer32 | .1.3.6.1.4.1.18070.2.2.1.1.2 |
| neSiteNum This is a network element site number used to uniquely
identify the site of the NE and to differentiate it from other
NE sites in the management domain. | scalar | Integer32 | .1.3.6.1.4.1.18070.2.2.1.1.3 |
| neDateAndTime The current system date and time, without time zone
information. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.1.4 |
| neTimeZone The time zone in which the local time of this system is to be
reported. Typically, the time zone is the one in which the
system is physically located. | scalar | BTI-TC-MIBTimeZone | .1.3.6.1.4.1.18070.2.2.1.1.5 |
| neAutoDST A setting that indicates whether the system time should be
updated automatically in accordance with the daylight savings
time characteristics of the current time zone. | scalar | Enumeration | .1.3.6.1.4.1.18070.2.2.1.1.6 |
| neGateway The default IP routing gateway for network management
interfaces on the node. If not specified, this object returns
a value of 0.0.0.0. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.18070.2.2.1.1.7 |
| neSecGateway The secondary IP routing gateway for network management
interfaces on the node. If not specified, this object returns
a value of 0.0.0.0. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.18070.2.2.1.1.8 |
| neActiveGateway The IP routing gateway that is currently active on the node.
If no gateway is active, this object returns a value of
0.0.0.0. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.18070.2.2.1.1.9 |