brcdMctClusterClientDeployFailureReason

BROCADE-MCT-CLUSTER-MIB · .1.3.6.1.4.1.1991.1.1.12.1.1.5.1.6

Object

column Enumeration
The failure reason for the last cluster client deploy operation
through SNMP. The following failure reasons are supported:
    none(1)                             - The last deploy is successful.
    unknown(2)                          - The last deploy is failed for
                                          unknown reason.
    rBridgeIdNotConfigured(3)           - Remote bridge is not
                                          configured.
    clientInterfaceNotConfigured(4)     - Client interface is not
                                          configured.
    rBridgeIdUsedInClusterOrPeer(5)     - Remote bridge id is used in
                                          cluster or peer configuration.
    clientInterfaceNotPresent(6)        - Client interface is physically
                                          not present
    clientInterfaceIsMrpRingInterface(7) - Client interface is
                                           configured as MRP ring
                                           interface.
    clientInterfaceIsErpInterface(8)    - Client interface is configured
                                          as ERP interface.
    iclIsNotInMemberVlan(9)             - ICL is not in member VLAN.

Context

MIB
BROCADE-MCT-CLUSTER-MIB
OID
.1.3.6.1.4.1.1991.1.1.12.1.1.5.1.6
Type
column
Access
readonly
Status
current
Parent
brcdMctClusterClientEntry
Table
brcdMctClusterClientTable
Siblings
6

Syntax

Enumeration

Values & Constraints

Enumerated Values
1none
2unknown
3rBridgeIdNotConfigured
4clientInterfaceNotConfigured
5rBridgeIdUsedInClusterOrPeer
6clientInterfacePhysicallyNotUp
7clientInterfaceIsMrpRingInterface
8clientInterfaceIsErpInterface
9iclIsNotInMemberVlan