cmDsCalCharacterizeNow

BRCM-CM-ENGINEERING-MIB · .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.17

Object

scalar r/w SNMPv2-TCTruthValue
When set to true(1), the CM will execute its DS characterization 
routine using the frequency specified by cmDsCalFrequency, and the 
modulation type specified by cmDsCalModulation.  Prior to executing the 
DS characterization routine, cmDsCalLockNow must have been set to 
true(1) and the lock must have been successful, as indicated by 
cmDsCalQamLocked and cmDsCalFecLocked both being true(1). The SET 
operation will not return until the routine is complete, so the SNMP 
manager's timeout value may need to be increased to several seconds.  
Once the DS characterization is complete, the resulting data may be 
read from the objects cmDsCalNormalLDAIT, cmDsCalNormalLDAIF, 
cmDsCalNormalLDAII, cmDsCalFrozenLDAIT, cmDsCalFrozenLDAIF, 
cmDsCalFrozenLDAII, cmDsCalFGain, cmDsCalTGain, and cmDsCalIGain.  
Always returns false(2) when read.

Context

MIB
BRCM-CM-ENGINEERING-MIB
OID
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.17
Type
scalar
Access
readwrite
Status
current
Parent
cmEngrDownstreamCalibration
Siblings
32

Syntax

SNMPv2-TCTruthValue
Source
SNMPv2-TCTruthValue
Base type
Enumeration

Values & Constraints

Type Values
1true
2false

Related Objects

Sibling Objects