battChargerHardwareFaultsAllowed

BRCM-BATTERY-MGMT-MIB · .1.3.6.1.4.1.4413.2.2.2.1.10.2.8

Object

scalar r/w HardwareFault
Specifies the hardware faults that are currently allowed to affect the
battery subsystem. If the charger does not support hardware faults then 
this object will not be supported. See bcmAlarmHardwareFault for a description
of appropriate usage. Default value is all faults enabled.

Context

MIB
BRCM-BATTERY-MGMT-MIB
OID
.1.3.6.1.4.1.4413.2.2.2.1.10.2.8
Type
scalar
Access
readwrite
Status
current
Parent
batteryCharger
Siblings
13

Syntax

HardwareFault
Source
HardwareFault
Base type
Bits

Values & Constraints

Type Values
0chargerOverVoltageFault
1chargerOverCurrentFault
3chargerPrequalVoltageFault
4chargerDischargeOverCurrentFault
5chargerGeneralDischargeFault
8chargerInputOverVoltageFault
9chargerUnexpectedBatteryVoltage
10chargerUnexpectedBatteryCurrent
11chargerBatteryOverVoltage
12chargerBatteryEnablesShorted

Related Objects