smIOCompatibility
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18
Object
column
mandatory
OctetString
The compatibility status for the I/O module.
The possible values and their meanings are as follows:
Unknown: This indicates a communication error for the I/O module.
OK: This is the normal (good) case where there are no compatibility
issues between the I/O module and the modules it is internally wired to.
No Fabric: This means the other end is not populated on any of the
modules this I/O module is internally wired to (e.g. this is an
Infiniband switch but none of the blades it is internally wired to
has an expansion card attached in the corresponding expansion slot).
Attention: Indicates one of the following cases:
One or more of the modules this I/O module is internally wired to is in communication error
The I/O module is powered off and at least one module it is internally wired to is powered on
Mismatch: Indicates one of the following cases:
Fabric types are incompatible
An unknown I/O module type
An unknown fabric type on a module the I/O module is internally wired to.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- smControlEntry
- Table
- smControlTable
- Siblings
- 12
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| smControlIndex mandatory Switch module control table index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1 |
| smHealthState mandatory The health state for the switch module.
0 = unknown, 1 = good, 2 = warning, 3 = bad. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15 |
| smPMState mandatory The Protected Mode Status for the switch module.
standby- Protected Mode capability exists on the IOM but has not
been activated on the switch module or the AMM.
pending - Protect… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16 |
| smPMCtrlEnableDisable mandatory AMM Protected Mode permission for the switch module.
disabled - allow AMM to disable Protected Mode Permission for the switch module.
enabled - allow AMM to grant Protected Mode P… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17 |
| switchModuleControlId mandatory The switch module numeric identifier. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2 |
| smPostResultsAvailable mandatory Describes whether the switch module POST diagnostic result
value contained in the smPostResultsValue is valid. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3 |
| smPostResultsValue mandatory The range of values and meanings are as follows:
0x00 - 0x7F ( 0 - 127) Base internal functions
0x80 - 0x9F (128 - 159) Internal interface failures
0xA0 - 0xAF (160 - 175) … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4 |
| switchModuleMemDiagEnableDisable mandatory Switch module memory diagnostics enabled or disabled.
NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional
(i.e. - 0 and… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5 |
| smCfgCtrlEnableDisable mandatory Switch module configuration control. When set to enabled, only the MM can manage
the module.
This MIB object can not be set, if AMM grants switch module the Protected Mode permis… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6 |
| smExtEthPortsEnableDisable mandatory Switch module external ethernet ports enabled or disabled.
This MIB object can not be set, if AMM grants switch module the
Protected Mode permission.
This MIB object can not be se… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7 |
| switchPingRequest obsolete Sends a ping to a switch module's current IPv4 address.
This MIB object can not be set, if AMM grants switch module the Protected Mode
permission and switch module goes into Prote… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.8 |
| smCfgCtrlOnResetEnableDisable mandatory Switch module configuration control on resets (default and unsolicited).
When set to enabled, the factory default IP configuration will become
active when the I/O module is reset … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9 |