fuelGaugeFirstPowerModule
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4
Object
column
mandatory
OctetString
Fuel Gauge Table First Power Module capacity in Watts in the power domain.
NOTE: First power module in power domain 1 and 2 is in bay 1
and 3 respectively.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- fuelGaugeEntry
- Table
- fuelGaugeTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fuelGaugeIndex mandatory Fuel Gauge Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1 |
| fuelGaugePowerInUsed mandatory This field displays the total power being used in each power domain.
When a 1200W or 1400W power module is installed in the domain
the power management policy will not be applicab… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10 |
| fuelGaugePowerDomainNumber mandatory Fuel Gauge Table Power Domain Number. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2 |
| fuelGaugeStatus mandatory Fuel Gauge Table Status for the power domain.
The response will start out with a numeric value (0 = unknown,
1 = good, 2 = warning, and 3: bad), followed by a text message. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3 |
| fuelGaugeSecondPowerModule mandatory Fuel Gauge Table Second Power Module capacity in Watts in the power domain.
NOTE: Second power module in power domain 1 and 2 is in bay 2
and 4 respectively. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.5 |
| fuelGaugePowerManagementPolicySetting mandatory Fuel Gauge Table for the Power Management Policy Setting for each power domain.
When a 1200W or 1400W power module is installed in the domain
the power management policy will not … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6 |
| fuelGaugeTotalPower mandatory This field displays the total available power for each power domain based on
installed power modules and the current Power Management Policy Setting.
When a 1200W or 1400W power m… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7 |
| fuelGaugeAllocatedPower mandatory This field displays the power that has been reserved in each power domain.
NOTE: 1) Power is always reserved in domain 1 for two management modules and
two I/O modules. 2) Power … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8 |
| fuelGaugeRemainingPower mandatory This field displays the remaining power available in each domain.
Remaining Power = Total Power minus Power In Use
When a 1200W or 1400W power module is installed in the domain
th… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9 |