fuelGaugeAllocatedPower
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8
Object
column
mandatory
OctetString
This field displays the power that has been reserved in each power domain. NOTE: 1) Power is always reserved in domain 1 for two management modules and two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and 4 (Powered on or standby). 3) Power is reserved for each installed Blade. Blades in a standby state (not powered on) will reserve a certain amount power. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- fuelGaugeEntry
- Table
- fuelGaugeTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fuelGaugeIndex mandatory Fuel Gauge Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1 |
| fuelGaugePowerInUsed mandatory This field displays the total power being used in each power domain.
When a 1200W or 1400W power module is installed in the domain
the power management policy will not be applicab… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10 |
| fuelGaugePowerDomainNumber mandatory Fuel Gauge Table Power Domain Number. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2 |
| fuelGaugeStatus mandatory Fuel Gauge Table Status for the power domain.
The response will start out with a numeric value (0 = unknown,
1 = good, 2 = warning, and 3: bad), followed by a text message. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3 |
| fuelGaugeFirstPowerModule mandatory Fuel Gauge Table First Power Module capacity in Watts in the power domain.
NOTE: First power module in power domain 1 and 2 is in bay 1
and 3 respectively. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4 |
| fuelGaugeSecondPowerModule mandatory Fuel Gauge Table Second Power Module capacity in Watts in the power domain.
NOTE: Second power module in power domain 1 and 2 is in bay 2
and 4 respectively. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.5 |
| fuelGaugePowerManagementPolicySetting mandatory Fuel Gauge Table for the Power Management Policy Setting for each power domain.
When a 1200W or 1400W power module is installed in the domain
the power management policy will not … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6 |
| fuelGaugeTotalPower mandatory This field displays the total available power for each power domain based on
installed power modules and the current Power Management Policy Setting.
When a 1200W or 1400W power m… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7 |
| fuelGaugeRemainingPower mandatory This field displays the remaining power available in each domain.
Remaining Power = Total Power minus Power In Use
When a 1200W or 1400W power module is installed in the domain
th… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9 |