x25PadProCRPadding
BIANCA-BRICK-X25PAD-MIB ·
.1.3.6.1.4.1.272.4.6.8.1.12
Object
column
mandatory
r/w
Integer32
The value of the parameter nine. This parameter provides for the automatic insertion by the PAD of padding characters in the character stream transmitted to the start-stop DTE after the occurrence of a carriage return character. This allows for the printing mechanism for the start-stop DTE to perform the carriage return function correctly. A value between 0 and 255 will indicate the number of padding characters. When this parameter is 0, there will be no padding except that PAD service signals will contain a number of padding characters according to the data rate of the start-stop DTE.
Context
- MIB
- BIANCA-BRICK-X25PAD-MIB
- OID
.1.3.6.1.4.1.272.4.6.8.1.12- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- x25PadProfileEntry
- Table
- x25PadProfileTable
- Siblings
- 34
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| x25PadProNumber mandatory The unique number of the profile. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.1 |
| x25PadProBrkControl mandatory The value of the parameter seven. This parameter allows the
selection of the operation of the PAD after the receipt of a
BREAK-signal from the start-stop DTE in data-transfer stat… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.10 |
| x25PadProDiscard mandatory The value of the parameter eight. This parameter provides for
a PAD to discard the content of user sequences in packets upon
request rather than disassembling and transmitting the… | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.11 |
| x25PadProLineFold mandatory The value of the parameter ten. This parameter provides for
the automatic insertion by the PAD of appropriate format
effectors in the character stream transmitted to the
start-sto… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.13 |
| x25PadProFlowControl mandatory The value of the parameter twelve. It allows for flow control
between the start-stop DTE and the PAD. The start-stop DTE
indicates whether it is ready or not to accept characters
… | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.14 |
| x25PadProLFInsert mandatory The value of the parameter thirteen. It provides for the
automatic insertion by the PAD of a linefeed character in
the character stream to or from the start-stop DTE after
each ca… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.15 |
| x25PadProLFPadding mandatory The value of the parameter fourteen. It provides for the
automatic insertion by the PAD of padding characters in the
character stream transmitted to the start-stop DTE after the
o… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.16 |
| x25PadProEdit mandatory The value of the parameter fifteen. It determines, whether
editing of user data in data-transfer state is possible or
not. The value 1 suspends data forwarding on full packet
unti… | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.17 |
| x25PadProCharDel mandatory The value of the parameter sixteen. This parameter provides
for character delete editing capabilities in the data-transfer
state for the start-stop DTE. The character defined by t… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.18 |
| x25PadProLineDel mandatory The value of the parameter seventeen. This parameter provides
for line delete editing capabilities in the data-transfer
state for the start-stop DTE. The character defined by the
… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.19 |
| x25PadProState mandatory The State of the profile. | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.2 |
| x25PadProLineDisp mandatory The value of the parameter eighteen. This parameter provides
for line display editing capabilities in the data-transfer
state for the start-stop DTE. The character defined by the
… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.20 |
| x25PadProSigEdit mandatory The value of the parameter nineteen. It provides the start-
stop DTE with the ability to decide whether or not editing PAD
service signals are transmitted and which format should … | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.21 |
| x25PadProEchoMask mandatory The value of the parameter twenty. When ECHO is enabled,
it allows selected defined sets of characters received from
the start-stop DTE not to be transmitted back to the
start-sto… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.22 |
| x25PadProParity mandatory The value of the parameter twenty one. It allows the PAD to
check parity in the data stream from the start-stop DTE and/or
generate parity in the data stream to the start-stop DTE… | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.23 |
| x25PadProPageWait mandatory The value of the parameter twenty two. It allows the PAD to
suspend transmission of additional characters to the start-
stop DTE after specified number of linefeed characters have… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.24 |
| x25PadProXCharDel mandatory The value of parameter one hundered eighteen. This parameter
is a repeating of parameter sixteen. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.25 |
| x25PadProXLineDel mandatory The value of parameter one hundered nineteen. This parameter
is a repeating of parameter seventeen. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.26 |
| x25PadProXLineDisp mandatory The value of the parameter one hundered twenty. This parameter
is a repeating of parameter eighteen. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.27 |
| x25PadProXForwardChar1 mandatory The value of the parameter one hundered twenty one. This
parameter allows predefinition of one data forwarding
character in addition to parameter three. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.28 |
| x25PadProXForwardChar2 mandatory The value of the parameter one hundered twenty two. This
parameter allows predefinition of one data forwarding
character in addition to parameter three. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.29 |
| x25PadProAutoCallDstAddr mandatory When this object is set to a non-empty string, a
call will automatically be established to this
PAD address. | column | - | .1.3.6.1.4.1.272.4.6.8.1.3 |
| x25PadProXParity mandatory The value of the parameter one hundered twenty three. This
corresponds to the parameter twenty one, but the meaning of
values 1 and 3 are interchanged. | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.30 |
| x25PadProXDelay mandatory The value of the parameter one hundered twenty five. This
parameter determines how long data forwarding ist delayed,
wenn it synces with a data entry. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.31 |
| x25PadProXLFInsert mandatory The value of the parameter one hundered twenty six. This is a
repeating of parameter thirteen. | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.32 |
| x25PadProIdent mandatory PAD Identification String, that is sent to start-stop
DTE, when PAD is started. | column | - | .1.3.6.1.4.1.272.4.6.8.1.33 |
| x25PadProTermAfterCall mandatory Terminate the PAD after X25 Call cleared | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.34 |
| x25PadProIgnoreX29 mandatory Ignore all X.29 messages | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.35 |
| x25PadProEscape mandatory The value of the parameter one. This parameter defines a
character on its receipt the PAD alternates the state
from data-transfer in connection-in-progress. This allows the
start-… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.4 |
| x25PadProEcho mandatory The value of the parameter two. This parameter determines
whether the echo mode is off or on. The selection of the
characters to be echoed is dependent on the value of
parameter E… | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.5 |
| x25PadProForwardChar mandatory The value of the parameter three. This parameter defines a
character. On its receipt the PAD forwards the previously
received data from start-stop DTE as packet. The value 0 mean… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.6 |
| x25PadProIdleTimer mandatory The value of parameter four. This parameter allows the
selection of the duration of an interval between successive
characters received from the start-stop DTE which, when
exceeded… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.7 |
| x25PadProDevControl mandatory The value of the parameter five. This parameter allows for
flow control between the PAD and the start-stop DTE. The PAD
indicates whether it is ready or not to accept characters
f… | column | Enumeration | .1.3.6.1.4.1.272.4.6.8.1.8 |
| x25PadProSigControl mandatory The value of the parameter six. This parameter provides the
start-stop DTE with the ability to decide whether or not and
in what format PAD service signals are transmitted. The va… | column | Integer32 | .1.3.6.1.4.1.272.4.6.8.1.9 |