BIANCA-BRICK-X25PAD-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
35

x25PadProfileTable

table mandatory
.1.3.6.1.4.1.272.4.6.8 · 1 row entry · 35 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk x25PadProfileTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BIANCA-BRICK-X25PAD-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-X25PAD-MIB::x25PadProfileTable'
This Table contains entries for the pad profiles. For PPP 
connections, pad profiles are assigned to incoming connections
via the isdnDispatchTable. For outgoing connections, the
profile is assigned by the biboPppTable. Profile 0 is used as
default profile for ppp.
x25PadProfileEntry row .1.3.6.1.4.1.272.4.6.8.1
Entries can only be created and deleted manually.
Indexes
Column Syntax OID
The unique number of the profile.
Integer32r/w
Constraints:
range: 0-99
.1.3.6.1.4.1.272.4.6.8.1.1
The State of the profile.
Enumerationr/w
Enumerated Values:
1valid
2delete
.1.3.6.1.4.1.272.4.6.8.1.2
When this object is set to a non-empty string, a
call will automatically be established to this
PAD address.
r/w .1.3.6.1.4.1.272.4.6.8.1.3
The value of the parameter one. This parameter defines a
character on its receipt the PAD alternates the state
from data-transfer in connection-in-progress. This allows the
start-stop mode DTE to initiate an escape from…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.4
x25PadProEchomandatory
The value of the parameter two. This parameter determines
whether the echo mode is off or on. The selection of the
characters to be echoed is dependent on the value of
parameter EchoMask.
Enumerationr/w
Enumerated Values:
1echo
256no-echo
.1.3.6.1.4.1.272.4.6.8.1.5
The value of the parameter three. This parameter defines a
character. On its receipt the PAD forwards the previously
received data from start-stop DTE as packet. The value 0 means
no data forwarding character.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.6
The value of parameter four. This parameter allows the
selection of the duration of an interval between successive
characters received from the start-stop DTE which, when
exceeded, will cause the PAD to terminate the as…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.7
The value of the parameter five. This parameter allows for
flow control between the PAD and the start-stop DTE. The PAD
indicates whether it is ready or not to accept characters
from the start-stop DTE by transmitting s…
Enumerationr/w
Enumerated Values:
1use-only-data-transfer
2use
256no-use
.1.3.6.1.4.1.272.4.6.8.1.8
The value of the parameter six. This parameter provides the
start-stop DTE with the ability to decide whether or not and
in what format PAD service signals are transmitted. The value
0 means no service signals are trans…
Integer32r/w
Constraints:
range: 0-7
.1.3.6.1.4.1.272.4.6.8.1.9
The value of the parameter seven. This parameter allows the
selection of the operation of the PAD after the receipt of a
BREAK-signal from the start-stop DTE in data-transfer state.
The value 0 indicates no operation. V…
Integer32r/w
Constraints:
range: 0-21
.1.3.6.1.4.1.272.4.6.8.1.10
The value of the parameter eight. This parameter provides for
a PAD to discard the content of user sequences in packets upon
request rather than disassembling and transmitting these to
the start-stop DTE.
Enumerationr/w
Enumerated Values:
1discard-output
256normal-data-delivery
.1.3.6.1.4.1.272.4.6.8.1.11
The value of the parameter nine. This parameter provides for
the automatic insertion by the PAD of padding characters in
the character stream transmitted to the start-stop DTE after
the occurrence of a carriage return c…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.12
The value of the parameter ten. This parameter provides for
the automatic insertion by the PAD of appropriate format
effectors in the character stream transmitted to the
start-stop DTE. The predetermined maximum number …
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.13
The value of the parameter twelve. It allows for flow control
between the start-stop DTE and the PAD. The start-stop DTE
indicates whether it is ready or not to accept characters
from the PAD by transmitting special cha…
Enumerationr/w
Enumerated Values:
1use-DC1-DC3
256no-use-DC1-DC3
.1.3.6.1.4.1.272.4.6.8.1.14
The value of the parameter thirteen. It provides for the
automatic insertion by the PAD of a linefeed character in
the character stream to or from the start-stop DTE after
each carriage return character. It applies only…
Integer32r/w
Constraints:
range: 0-7
.1.3.6.1.4.1.272.4.6.8.1.15
The value of the parameter fourteen. It provides for the
automatic insertion by the PAD of padding characters in the
character stream transmitted to the start-stop DTE after the
occurrence of a linefeed character. It ap…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.16
x25PadProEditmandatory
The value of the parameter fifteen. It determines, whether
editing of user data in data-transfer state is possible or
not. The value 1 suspends data forwarding on full packet
until the editing buffer is full and data fo…
Enumerationr/w
Enumerated Values:
1editing-user-data
256no-editing-user-data
.1.3.6.1.4.1.272.4.6.8.1.17
The value of the parameter sixteen. This parameter provides
for character delete editing capabilities in the data-transfer
state for the start-stop DTE. The character defined by the
user for character delete is the bina…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.18
The value of the parameter seventeen. This parameter provides
for line delete editing capabilities in the data-transfer
state for the start-stop DTE. The character defined by the
user for line delete is the binary respr…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.19
The value of the parameter eighteen. This parameter provides
for line display editing capabilities in the data-transfer
state for the start-stop DTE. The character defined by the
user for line display is the binary resp…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.20
The value of the parameter nineteen. It provides the start-
stop DTE with the ability to decide whether or not editing PAD
service signals are transmitted and which format should be
used. This parameter does not apply i…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.21
The value of the parameter twenty. When ECHO is enabled,
it allows selected defined sets of characters received from
the start-stop DTE not to be transmitted back to the
start-stop DTE. Value 64 does not apply if editin…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.22
The value of the parameter twenty one. It allows the PAD to
check parity in the data stream from the start-stop DTE and/or
generate parity in the data stream to the start-stop DTE.
Characters generated by the PAD itself…
Enumerationr/w
Enumerated Values:
1parity-checking
2parity-generation
3parity-checking-generation
256no-parity
.1.3.6.1.4.1.272.4.6.8.1.23
The value of the parameter twenty two. It allows the PAD to
suspend transmission of additional characters to the start-
stop DTE after specified number of linefeed characters have
been transmitted by the PAD. Value 0 de…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.24
The value of parameter one hundered eighteen. This parameter
is a repeating of parameter sixteen.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.25
The value of parameter one hundered nineteen. This parameter
is a repeating of parameter seventeen.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.26
The value of the parameter one hundered twenty. This parameter
is a repeating of parameter eighteen.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.27
The value of the parameter one hundered twenty one. This
parameter allows predefinition of one data forwarding
character in addition to parameter three.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.28
The value of the parameter one hundered twenty two. This
parameter allows predefinition of one data forwarding
character in addition to parameter three.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.29
The value of the parameter one hundered twenty three. This
corresponds to the parameter twenty one, but the meaning of
values 1 and 3 are interchanged.
Enumerationr/w
Enumerated Values:
1parity-checking-generation
2parity-generation
3parity-checking
256no-parity
.1.3.6.1.4.1.272.4.6.8.1.30
The value of the parameter one hundered twenty five. This
parameter determines how long data forwarding ist delayed,
wenn it synces with a data entry.
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.272.4.6.8.1.31
The value of the parameter one hundered twenty six. This is a
repeating of parameter thirteen.
Integer32r/w
Constraints:
range: 0-7
.1.3.6.1.4.1.272.4.6.8.1.32
PAD Identification String, that is sent to start-stop
DTE, when PAD is started.
r/w .1.3.6.1.4.1.272.4.6.8.1.33
Terminate the PAD after X25 Call cleared
Enumerationr/w
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.272.4.6.8.1.34
Ignore all X.29 messages
Enumerationr/w
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.272.4.6.8.1.35