pmxIfLayer1Framing
BIANCA-BRICK-PMX-MIB ·
.1.3.6.1.4.1.272.4.12.1.1.5
Object
column
mandatory
r/w
Enumeration
In T1 and E1 mode the primary rate interface can work
with totaly different framing types on layer 1. The
framing type must match the configuration of the
first connected point e.g. the exchange or the NT
e1(1) E1 - minimum mode, CCITT Recommendation G.704
(Table 4a)
e1-crc(2) E1 , crc mode, CCITT Recommendation G.704
(Table 4b)
e1-mf(3) E1 , CCITT Recommendation G.704 (Table 4a)
with Timeslot 16 multiframing enabled
e1-mf-crc(4) E1 , CCITT Recommendation G.704 (Table 4b)
with Timeslot 16 multiframing enabled
t1-esf(5) T1 , Extended SuperFrame mode DS1
t1-d4(6) T1 , AT&T D4 format DS1
t1-framings can only be set when pmxIfLayer1Mode is t1
e1-framings can only be set when pmxIfLayer1Mode is e1
The default framing for t1 is t1-esf, the default framing
for e1 is e1-crc
Modifications of the default values are usualy not required.
Exceptions are only known for sweden and france (use e1)
Context
- MIB
- BIANCA-BRICK-PMX-MIB
- OID
.1.3.6.1.4.1.272.4.12.1.1.5- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- pmxIfEntry
- Table
- pmxIfTable
- Siblings
- 16
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | e1 |
2 | e1-mf |
3 | e1-crc |
4 | e1-mf-crc |
5 | t1-esf |
6 | t1-d4 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pmxIfIndex mandatory Unique Index of the primary rate interface. The index
is similar to slotnumber * 1000 and is also refenced in
the ifTable, the isdnIfTable and in the isdnStkTable | column | Integer32 | .1.3.6.1.4.1.272.4.12.1.1.1 |
| pmxIfPortMode mandatory PortMode switches the CM-PRI's 'Out'-port
normal(1) 'Out'-port is disabled, this
CM-PRI is connected to 'In'
go-thru(2) 'Out'-port is enabled, this
CM-PRI i… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.10 |
| pmxIfSelftest mandatory The result of the initial selftest of the PMX module
If the result is not succesful, the module is disabled
successful(1) All selftests succeeded;
acfa-failure(2)… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.2 |
| pmxIfLOS mandatory Loss Of Signal conditions since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.21 |
| pmxIfNoFAS mandatory Loss Of Frame Alignment conditions since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.22 |
| pmxIfRemoteAlarms mandatory Remote Alarms received since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.23 |
| pmxIfAlarmInds mandatory Alarms received since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.24 |
| pmxIfCRC4Errors mandatory CRC4 errors detected since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.25 |
| pmxIfSlipPositive mandatory Positive Slip conditions detected since startup;
flags that the frequency of receive clock is less
than frequency of internal system clock | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.26 |
| pmxIfSlipNegative mandatory Negative Slip conditions detected since startup;
flags that the frequency of receive clock is greater
than frequency of internal system clock | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.27 |
| pmxIfLayer1State mandatory The layer 1 state of the primary rate interface
active(F1) active, framing and synchronisation
is o.k. This is the only state where
data-transmission is poss… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.3 |
| pmxIfLayer1Mode mandatory In T1 and E1 mode the primary rate interface is working
with totaly different clock frequencies, framing and
impedance. This depends on one of the jumpers on the
PMX module. For… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.4 |
| pmxIfLayer1LineCode mandatory In T1 mode the primary rate interface is able
to work with different line codes.
e1-hdb3(1) High Density Bipolar 3 Level Coding
This is the only valid line… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.6 |
| pmxIfChannelMode mandatory In T1 and E1 mode the primary rate interface may work
with different channel types. Usually every timeslot
is similar to one channel but it is also possible to
bundle multiple … | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.7 |
| pmxIfLoopbackMode mandatory Loopback-Mode is only required for equipment test
no-loop(1) do not loopanything, this is the
correct mode for normal operation
full-loop(2) loopback everythi… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.8 |
| pmxIfErrors mandatory The measured PMX interface errors since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.9 |