BIANCA-BRICK-PMX-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
17

pmxIfTable

table mandatory
.1.3.6.1.4.1.272.4.12.1 · 1 row entry · 17 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk pmxIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BIANCA-BRICK-PMX-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-PMX-MIB::pmxIfTable'
The pmxIfTable contains information relating to the 
interfaces found on the system. Each entry corresponds to
a connected primary rate interface. Entries can only be 
	added or deleted by the system. 
          
Creating entries: Entries are created by the system
only when a new PMX module is installed.
          
Deleting entries: Entries are removed by the system
after the appropriate PMX module is removed.
pmxIfEntry row .1.3.6.1.4.1.272.4.12.1.1
Indexes
Column Syntax OID
pmxIfIndexmandatory
Unique Index of the primary rate interface. The index
is similar to slotnumber * 1000 and is also refenced in
the ifTable, the isdnIfTable and in the isdnStkTable
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.272.4.12.1.1.1
pmxIfSelftestmandatory
The result of the initial selftest of the PMX module
If the result is not succesful, the module is disabled

successful(1) All selftests succeeded;
acfa-failure(2) failure with the module ACFA Chip
m32-f…
Enumeration
Enumerated Values:
1successful
2acfa-failure
3m32-failure
4mem-failure
.1.3.6.1.4.1.272.4.12.1.1.2
The layer 1 state of the primary rate interface

active(F1) active, framing and synchronisation
is o.k. This is the only state where
data-transmission is possible
remote-alarm(F2) receipt of an RAI,…
Enumerationr/w
Enumerated Values:
1active
2remote-alarm
3no-signal
4no-sync
5crc-error
6power-on
7resync
.1.3.6.1.4.1.272.4.12.1.1.3
In T1 and E1 mode the primary rate interface is working
with totaly different clock frequencies, framing and
impedance. This depends on one of the jumpers on the
PMX module. For correct operation all 5 jumpers must be…
Enumeration
Enumerated Values:
1e1
2t1
.1.3.6.1.4.1.272.4.12.1.1.4
In T1 and E1 mode the primary rate interface can work
with totaly different framing types on layer 1. The
framing type must match the configuration of the
first connected point e.g. the exchange or the NT
Enumerationr/w
Enumerated Values:
1e1
2e1-mf
3e1-crc
4e1-mf-crc
5t1-esf
6t1-d4
.1.3.6.1.4.1.272.4.12.1.1.5
In T1 mode the primary rate interface is able
to work with different line codes.

e1-hdb3(1) High Density Bipolar 3 Level Coding
This is the only valid linecoding for E1
t1-b8zs(2) Bipolar 8 …
Enumerationr/w
Enumerated Values:
1e1-hdb3
2t1-b8zs
3t1-ami
.1.3.6.1.4.1.272.4.12.1.1.6
In T1 and E1 mode the primary rate interface may work
with different channel types. Usually every timeslot
is similar to one channel but it is also possible to
bundle multiple timeslots to one channel with a higher
Enumerationr/w
Enumerated Values:
1e1-standard
2e1-1tr6
3e1-H0
4e1-H12
5e1-burst
6e1-raw
7e1-leased
10t1-standard
11t1-H0
12t1-H11
13t1-burst
14t1-raw
15t1-leased
.1.3.6.1.4.1.272.4.12.1.1.7
Loopback-Mode is only required for equipment test

no-loop(1) do not loopanything, this is the
correct mode for normal operation
full-loop(2) loopback everything incl. the
signaling channel
all-c…
Enumerationr/w
Enumerated Values:
1no-loop
2full-loop
3all-channels
4only-bchannels
.1.3.6.1.4.1.272.4.12.1.1.8
pmxIfErrorsmandatory
The measured PMX interface errors since startup
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.9
pmxIfPortModemandatory
PortMode switches the CM-PRI's 'Out'-port

normal(1) 'Out'-port is disabled, this
CM-PRI is connected to 'In'
go-thru(2) 'Out'-port is enabled, this
CM-PRI is disconnected.
go-thru-tst(3) same as …
Enumerationr/w
Enumerated Values:
1normal
2go-thru
3go-thru-tst
.1.3.6.1.4.1.272.4.12.1.1.10
pmxIfLOSmandatory
Loss Of Signal conditions since startup
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.21
pmxIfNoFASmandatory
Loss Of Frame Alignment conditions since startup
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.22
Remote Alarms received since startup
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.23
Alarms received since startup
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.24
CRC4 errors detected since startup
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.25
Positive Slip conditions detected since startup;
flags that the frequency of receive clock is less
than frequency of internal system clock
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.26
Negative Slip conditions detected since startup;
flags that the frequency of receive clock is greater
than frequency of internal system clock
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.12.1.1.27