pmxIfChannelMode
BIANCA-BRICK-PMX-MIB ·
.1.3.6.1.4.1.272.4.12.1.1.7
Object
column
mandatory
r/w
Enumeration
In T1 and E1 mode the primary rate interface may work
with different channel types. Usually every timeslot
is similar to one channel but it is also possible to
bundle multiple timeslots to one channel with a higher
bandwith. This channel bundeling is currently not
supported by the switching equipment for dialup
connections of any network-provider. But usage is
possible with leased lines.
e1-standard(1) 1 D-channel 64 kbit, 30 B-channels 64kbit
bchannels are numbered from 1 to 15 and
from 16 to 31
e1-1tr6(2) 1 D-channel 64 kbit, 30 B-channels 64kbit
identical timeslotassignment as e1-standard
but bchannels are numbered from 1 to 30
e1-H0(3) 1 D-channel 64 kbit, 5 B-channels 384kbit
bchannels are numbered from 1 to 5
e1-H12(4) 1 D-channel 64 kbit, 1 B-channel 1920kbit
e1-burst(5) 1 channel 1984kbit, channel number is 0
e1-raw(6) 1 channel 2048kbit, channel number is 0
e1-leased(7) 31 B-channels 64kbit, numbered from 1 to 31
t1-standard(6) 1 D-channel 64 kbit, 23 B-channels 64kbit
bchannels are numbered from 1 to 23
t1-H0(7) 1 D-channel 64 kbit, 4 B-channels 384kbit
bchannels are numbered from 1 to 4
t1-H11(8) 1 D-channel 64 kbit, 1 B-channel 1472kbit
t1-burst(9) 1 channel 1536kbit, channel number is 0
t1-channelmodes can only be set when pmxIfLayer1Mode is t1
e1-channelmodes can only be set when pmxIfLayer1Mode is e1
Context
- MIB
- BIANCA-BRICK-PMX-MIB
- OID
.1.3.6.1.4.1.272.4.12.1.1.7- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- pmxIfEntry
- Table
- pmxIfTable
- Siblings
- 16
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | e1-standard |
2 | e1-1tr6 |
3 | e1-H0 |
4 | e1-H12 |
5 | e1-burst |
6 | e1-raw |
7 | e1-leased |
10 | t1-standard |
11 | t1-H0 |
12 | t1-H11 |
13 | t1-burst |
14 | t1-raw |
15 | t1-leased |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pmxIfIndex mandatory Unique Index of the primary rate interface. The index
is similar to slotnumber * 1000 and is also refenced in
the ifTable, the isdnIfTable and in the isdnStkTable | column | Integer32 | .1.3.6.1.4.1.272.4.12.1.1.1 |
| pmxIfPortMode mandatory PortMode switches the CM-PRI's 'Out'-port
normal(1) 'Out'-port is disabled, this
CM-PRI is connected to 'In'
go-thru(2) 'Out'-port is enabled, this
CM-PRI i… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.10 |
| pmxIfSelftest mandatory The result of the initial selftest of the PMX module
If the result is not succesful, the module is disabled
successful(1) All selftests succeeded;
acfa-failure(2)… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.2 |
| pmxIfLOS mandatory Loss Of Signal conditions since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.21 |
| pmxIfNoFAS mandatory Loss Of Frame Alignment conditions since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.22 |
| pmxIfRemoteAlarms mandatory Remote Alarms received since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.23 |
| pmxIfAlarmInds mandatory Alarms received since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.24 |
| pmxIfCRC4Errors mandatory CRC4 errors detected since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.25 |
| pmxIfSlipPositive mandatory Positive Slip conditions detected since startup;
flags that the frequency of receive clock is less
than frequency of internal system clock | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.26 |
| pmxIfSlipNegative mandatory Negative Slip conditions detected since startup;
flags that the frequency of receive clock is greater
than frequency of internal system clock | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.27 |
| pmxIfLayer1State mandatory The layer 1 state of the primary rate interface
active(F1) active, framing and synchronisation
is o.k. This is the only state where
data-transmission is poss… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.3 |
| pmxIfLayer1Mode mandatory In T1 and E1 mode the primary rate interface is working
with totaly different clock frequencies, framing and
impedance. This depends on one of the jumpers on the
PMX module. For… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.4 |
| pmxIfLayer1Framing mandatory In T1 and E1 mode the primary rate interface can work
with totaly different framing types on layer 1. The
framing type must match the configuration of the
first connected poi… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.5 |
| pmxIfLayer1LineCode mandatory In T1 mode the primary rate interface is able
to work with different line codes.
e1-hdb3(1) High Density Bipolar 3 Level Coding
This is the only valid line… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.6 |
| pmxIfLoopbackMode mandatory Loopback-Mode is only required for equipment test
no-loop(1) do not loopanything, this is the
correct mode for normal operation
full-loop(2) loopback everythi… | column | Enumeration | .1.3.6.1.4.1.272.4.12.1.1.8 |
| pmxIfErrors mandatory The measured PMX interface errors since startup | column | RFC1155-SMICounter | .1.3.6.1.4.1.272.4.12.1.1.9 |