atmSoftPVpcRetryLimit

ATM-SOFT-PVC-MIB · .1.3.6.1.4.1.353.5.5.1.1.3.1.13

Object

column r/w Integer32
Sets a maximum limit on how many consecutive unsuccessful
call setup attempts can be made before stopping the attempt
to set up the connection. If this limit is reached then
management action will be required (e.g. setting
atmSoftPVpcRestart to 'restart') to initiate a new attempt
to establish the connection. A value of zero indicates no
limit - the attempts will continue until successful.

Context

MIB
ATM-SOFT-PVC-MIB
OID
.1.3.6.1.4.1.353.5.5.1.1.3.1.13
Type
column
Access
readwrite
Status
current
Parent
atmSoftPVpcEntry
Table
atmSoftPVpcTable
Siblings
13

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects

Sibling Objects