swPortMgtIndex
ATI-8324SX-MIB ·
.1.3.6.1.4.1.207.1.4.42.2.1.1.1
Object
column
SNMPv2-SMIInteger32
This object identifies the port within the switch for which this entry contains information.
Context
- MIB
- ATI-8324SX-MIB
- OID
.1.3.6.1.4.1.207.1.4.42.2.1.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- switchPortMgtEntry
- Table
- switchPortMgtTable
- Siblings
- 5
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| swPortMgtPortType Indicates the port type. | column | Enumeration | .1.3.6.1.4.1.207.1.4.42.2.1.1.2 |
| swPortMgtSpeedDpxAdmin Set the port speed and duplex mode as follows:
halfDuplex10(1) - 10Mbps and half duplex mode
fullDuplex10(2) - 10Mbps and full duplex mode
halfDuplex100(3) - 100Mbps and h… | column | Enumeration | .1.3.6.1.4.1.207.1.4.42.2.1.1.3 |
| swPortMgtSpeedDpxInUse The operating speed and duplex mode of the
switched port. | column | Enumeration | .1.3.6.1.4.1.207.1.4.42.2.1.1.4 |
| swPortMgtFlowCtrlAdmin (1) Flow control mechanism is enabled.
If the port type is hundredBaseTX or thousandBaseSX:
When the port is operating in halfDuplex mode, the
port uses backPressure flow control … | column | Enumeration | .1.3.6.1.4.1.207.1.4.42.2.1.1.5 |
| swPortMgtFlowCtrlInUse (1) BackPressure flow control machanism is used.
(2) IEEE 802.3 flow control machanism is used.