atFiberMonSensitivity
AT-FIBER-MONITORING-MIB ·
.1.3.6.1.4.1.207.8.4.4.3.27.2.1.4
Object
column
r/w
OctetString
The sensitivity for fiber monitoring.
Acceptable mode strings and value ranges are as below:
low - 2dB
medium - 1dB
high - 0.5dB
highest - 0.0025mW
fixed <25 - 65535> - units of 0.0001mW
relative <0.00 - 10.00> - units of dB
For example, if you want to set the sensitivity to medium level, then you enter word
medium
Or if you want to set it to a fixed value, then you enter string
fixed 1000
Or if you want to set to a relative value, then you enter string
relative 1.20
Context
- MIB
- AT-FIBER-MONITORING-MIB
- OID
.1.3.6.1.4.1.207.8.4.4.3.27.2.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- atFiberMonConfigEntry
- Table
- atFiberMonConfigTable
- Siblings
- 5
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| atFiberMonIfname The name of the interface where the pluggable is in. | column | OctetString | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.1 |
| atFiberMonEnable Enable or disable fiber monitoring. | column | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.2 |
| atFiberMonInterval Fiber monitoring polling interval in seconds. | column | Integer32 | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.3 |
| atFiberMonBaseline The baseline value for firber mornitoring.
Acceptable mode string and value ranges are as below:
average <12-150> - number of readings used to calcul… | column | OctetString | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.5 |
| atFiberMonAlarmAction Actions to take when an alarm occurs.
Acceptable values are:
1. Log a message only.
2. Send snmp trap and log.
3. Shut down the interface and log.
4. Send trap, shutdown and log. | column | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.6 |