atFiberMonBaseline
AT-FIBER-MONITORING-MIB ·
.1.3.6.1.4.1.207.8.4.4.3.27.2.1.5
Object
column
r/w
OctetString
The baseline value for firber mornitoring.
Acceptable mode string and value ranges are as below:
average <12-150> - number of readings used to calculate moving average.
fixed <1-65535> - fixed baseline value in units of 0.0001mW.
For example, if you want to use a moving average of 12 readings as the baseline,
you enter
average 12
Or if you want to use a fixed value, though it is not recommended, you enter
fixed 500
Context
- MIB
- AT-FIBER-MONITORING-MIB
- OID
.1.3.6.1.4.1.207.8.4.4.3.27.2.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- atFiberMonConfigEntry
- Table
- atFiberMonConfigTable
- Siblings
- 5
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| atFiberMonIfname The name of the interface where the pluggable is in. | column | OctetString | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.1 |
| atFiberMonEnable Enable or disable fiber monitoring. | column | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.2 |
| atFiberMonInterval Fiber monitoring polling interval in seconds. | column | Integer32 | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.3 |
| atFiberMonSensitivity The sensitivity for fiber monitoring.
Acceptable mode strings and value ranges are as below:
low - 2dB
medium … | column | OctetString | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.4 |
| atFiberMonAlarmAction Actions to take when an alarm occurs.
Acceptable values are:
1. Log a message only.
2. Send snmp trap and log.
3. Shut down the interface and log.
4. Send trap, shutdown and log. | column | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.27.2.1.6 |