raidStatusChange
ASYNCOS-MAIL-MIB ·
.1.3.6.1.4.1.15497.1.1.2.7
Object
notification
A raidStatusChange notification is sent when drive with raidID changes states, as per one of the states available in raidStatus. This notification contains the opaque type for raidID of the drive which has changed state.
Context
- MIB
- ASYNCOS-MAIL-MIB
- OID
.1.3.6.1.4.1.15497.1.1.2.7- Type
- notification
- Status
- current
- Parent
- asyncOSMailNotifications
- Siblings
- 11
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| resourceConservationMode Memory or queue utilization caused system to enter resource
conservation mode. | notification | - | .1.3.6.1.4.1.15497.1.1.2.1 |
| cpuUtilizationExceeded A cpuUtilizationExceeded notification is sent when the
value in perCentCPUUtilization has exceeded the configured
CPU usage threshold. The percentage that exceeded the
threshold i… | notification | - | .1.3.6.1.4.1.15497.1.1.2.10 |
| hsmInitializationFailure A hsmInitializationFailure notification is sent when the
Hardware Security Module card cannot be initialized. The
initialization error in hsmErrorReason is returned via
the notifi… | notification | - | .1.3.6.1.4.1.15497.1.1.2.11 |
| hsmResetLoginFailure A hsmResetLoginFailure notification is sent when the
Hardware Security Module card is reset due to multiple
Crypto Officer login failures. The reset login error in
hsmErrorReason … | notification | - | .1.3.6.1.4.1.15497.1.1.2.12 |
| powerSupplyStatusChange A powerSupplyStatusChange notification is sent when power
supply with powerSupplyName changes states, as per one of
the states available in powerSupplyStatus. This
notification co… | notification | - | .1.3.6.1.4.1.15497.1.1.2.2 |
| highTemperature A highTemperature notification is sent when the temperature
of an instrumented sensor in the chassis has exceeded vendor
defined specifications. This notification contains the
opa… | notification | - | .1.3.6.1.4.1.15497.1.1.2.3 |
| fanFailure A fanFailure notification is sent when the speed of the fan
is not operating per the vendor defined specifications, as
discussed in fanRPMs. This notification contains the opaque
… | notification | - | .1.3.6.1.4.1.15497.1.1.2.4 |
| keyExpiration A keyExpiration notification is sent when the corresponding
Feature Key is pending expiration or has expired. This
notification contains the opaque type for the keyDescription
of … | notification | - | .1.3.6.1.4.1.15497.1.1.2.5 |
| updateFailure An updateFailure notification is sent when a service fails
to update properly. This notification contains the opaque
type for the updateServiceName of the update service that
has … | notification | - | .1.3.6.1.4.1.15497.1.1.2.6 |
| connectivityFailure A connectivityFailure notification is sent when the URL
denoted by configured connectionURL is unreachable, or the
request returned an HTTP code was not between 200,
inclusive, an… | notification | - | .1.3.6.1.4.1.15497.1.1.2.8 |
| memoryUtilizationExceeded A memoryUtilizationExceeded notification is sent when the
value in perCentMemoryUtilization has exceeded the
configured memory usage threshold. The percentage that
exceeded the th… | notification | - | .1.3.6.1.4.1.15497.1.1.2.9 |