ASYNCOS-MAIL-MIB

        MIB for Cisco IronPort Mail Gateway/Email Security Appliances
    
asyncOSMailObjects 1.3.6.1.4.1.15497.1.1.1
Imported Objects
IRONPORT-SMI asyncOSMail
SNMPv2-SMI Counter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TC DisplayString TruthValue
Objects (52)
asyncOSMailObjects .1.3.6.1.4.1.15497.1.1.1
perCentMemoryUtilization Integer32 .1.3.6.1.4.1.15497.1.1.1.1
fanTable .1.3.6.1.4.1.15497.1.1.1.10
fanEntry fanIndex .1.3.6.1.4.1.15497.1.1.1.10.1
fanIndex Integer32 .1.3.6.1.4.1.15497.1.1.1.10.1.1
fanRPMs SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.10.1.2
fanName SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.10.1.3
workQueueMessages SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.11
keyExpirationTable .1.3.6.1.4.1.15497.1.1.1.12
keyExpirationEntry keyExpirationIndex .1.3.6.1.4.1.15497.1.1.1.12.1
keyExpirationIndex Integer32 .1.3.6.1.4.1.15497.1.1.1.12.1.1
keyDescription SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.12.1.2
keyIsPerpetual SNMPv2-TCTruthValue .1.3.6.1.4.1.15497.1.1.1.12.1.3
keySecondsUntilExpire SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.12.1.4
updateTable .1.3.6.1.4.1.15497.1.1.1.13
updateEntry updateIndex .1.3.6.1.4.1.15497.1.1.1.13.1
updateIndex Integer32 .1.3.6.1.4.1.15497.1.1.1.13.1.1
updateServiceName SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.13.1.2
updates SNMPv2-SMICounter32 .1.3.6.1.4.1.15497.1.1.1.13.1.3
updateFailures SNMPv2-SMICounter32 .1.3.6.1.4.1.15497.1.1.1.13.1.4
oldestMessageAge SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.14
outstandingDNSRequests SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.15
pendingDNSRequests SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.16
raidEvents SNMPv2-SMICounter32 .1.3.6.1.4.1.15497.1.1.1.17
raidTable .1.3.6.1.4.1.15497.1.1.1.18
raidEntry raidIndex .1.3.6.1.4.1.15497.1.1.1.18.1
raidIndex Integer32 .1.3.6.1.4.1.15497.1.1.1.18.1.1
raidStatus Enumeration .1.3.6.1.4.1.15497.1.1.1.18.1.2
raidID SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.18.1.3
raidLastError SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.18.1.4
openFilesOrSockets SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.19
perCentCPUUtilization Integer32 .1.3.6.1.4.1.15497.1.1.1.2
mailTransferThreads SNMPv2-SMIGauge32 .1.3.6.1.4.1.15497.1.1.1.20
connectionURL SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.21
hsmErrorReason SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.22
perCentDiskIOUtilization Integer32 .1.3.6.1.4.1.15497.1.1.1.3
perCentQueueUtilization Integer32 .1.3.6.1.4.1.15497.1.1.1.4
queueAvailabilityStatus Enumeration .1.3.6.1.4.1.15497.1.1.1.5
resourceConservationReason Enumeration .1.3.6.1.4.1.15497.1.1.1.6
memoryAvailabilityStatus Enumeration .1.3.6.1.4.1.15497.1.1.1.7
powerSupplyTable .1.3.6.1.4.1.15497.1.1.1.8
powerSupplyEntry powerSupplyIndex .1.3.6.1.4.1.15497.1.1.1.8.1
powerSupplyIndex Integer32 .1.3.6.1.4.1.15497.1.1.1.8.1.1
powerSupplyStatus Enumeration .1.3.6.1.4.1.15497.1.1.1.8.1.2
powerSupplyRedundancy Enumeration .1.3.6.1.4.1.15497.1.1.1.8.1.3
powerSupplyName SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.8.1.4
temperatureTable .1.3.6.1.4.1.15497.1.1.1.9
temperatureEntry temperatureIndex .1.3.6.1.4.1.15497.1.1.1.9.1
temperatureIndex Integer32 .1.3.6.1.4.1.15497.1.1.1.9.1.1
degreesCelsius Integer32 .1.3.6.1.4.1.15497.1.1.1.9.1.2
temperatureName SNMPv2-TCDisplayString .1.3.6.1.4.1.15497.1.1.1.9.1.3
asyncOSMailNotifications .1.3.6.1.4.1.15497.1.1.2
Notifications / Traps (12)
NameOIDDescription
resourceConservationMode .1.3.6.1.4.1.15497.1.1.2.1
Memory or queue utilization caused system to enter resource
conservation mode.
cpuUtilizationExceeded .1.3.6.1.4.1.15497.1.1.2.10
A cpuUtilizationExceeded notification is sent when the
value in perCentCPUUtilization has exceeded the configured
CPU usage threshold. The percentage that exceeded the
threshold in perCentCPUUtilization is returned via the
notification.
hsmInitializationFailure .1.3.6.1.4.1.15497.1.1.2.11
A hsmInitializationFailure notification is sent when the
Hardware Security Module card cannot be initialized. The
initialization error in hsmErrorReason is returned via
the notification.
hsmResetLoginFailure .1.3.6.1.4.1.15497.1.1.2.12
A hsmResetLoginFailure notification is sent when the
Hardware Security Module card is reset due to multiple
Crypto Officer login failures. The reset login error in
hsmErrorReason is returned via the notification.
powerSupplyStatusChange .1.3.6.1.4.1.15497.1.1.2.2
A powerSupplyStatusChange notification is sent when power
supply with powerSupplyName changes states, as per one of
the states available in powerSupplyStatus. This
notification contains the opaque type for powerSupplyName
of the power supply which has changed state.
highTemperature .1.3.6.1.4.1.15497.1.1.2.3
A highTemperature notification is sent when the temperature
of an instrumented sensor in the chassis has exceeded vendor
defined specifications. This notification contains the
opaque type for the temperatureName of the sensor which has
failed.
fanFailure .1.3.6.1.4.1.15497.1.1.2.4
A fanFailure notification is sent when the speed of the fan
is not operating per the vendor defined specifications, as
discussed in fanRPMs. This notification contains the opaque
type for the fanName of the fan which has failed.
keyExpiration .1.3.6.1.4.1.15497.1.1.2.5
A keyExpiration notification is sent when the corresponding
Feature Key is pending expiration or has expired. This
notification contains the opaque type for the keyDescription
of the Feature Key that is pending expiration or has
expired.
updateFailure .1.3.6.1.4.1.15497.1.1.2.6
An updateFailure notification is sent when a service fails
to update properly. This notification contains the opaque
type for the updateServiceName of the update service that
has failed.
raidStatusChange .1.3.6.1.4.1.15497.1.1.2.7
A raidStatusChange notification is sent when drive with
raidID changes states, as per one of the states available
in raidStatus. This notification contains the opaque type
for raidID of the drive which has changed state.
connectivityFailure .1.3.6.1.4.1.15497.1.1.2.8
A connectivityFailure notification is sent when the URL
denoted by configured connectionURL is unreachable, or the
request returned an HTTP code was not between 200,
inclusive, and 300, exclusive. The connectionURL configured
is returned when the notification is triggered.
memoryUtilizationExceeded .1.3.6.1.4.1.15497.1.1.2.9
A memoryUtilizationExceeded notification is sent when the
value in perCentMemoryUtilization has exceeded the
configured memory usage threshold. The percentage that
exceeded the threshold in perCentMemoryUtilization is
returned via the notification.