fsLaPortChannelDLAGPeriodicSyncTime

ARICENT-LA-MIB · .1.3.6.1.4.1.2076.63.2.1.1.15

Object

column r/w milliseconds Unsigned32
This object is used to configure the D-LAG periodic sync timer
used in distributed link aggregation.
Periodic sync timer is used to configure the transmission
interval of D-LAG periodic-sync PDUs. Periodic-sync timer
will be running individually in each D-LAG node.
              
if this object is configured with a value of '0', then no
periodic-sync messages will be sent from that D-LAG node.
              
The configured value of this timer is applicable only
from the next start/re-start of the timer.
              
Value of this object should be same in all D-LAG nodes,
configuring this object to different values across the
D-LAG nodes of the same D-LAG may result in deletion of 
maintained neighbor node information because of keep alive
mechanism and when D-LAG redundancy feature is enabled,
then repeated toggling of role played by D-LAG nodes may
be observed.
              
The periodic sync timer has a period from 0 to 90 seconds,
configurable in units of 1 ms. For example, to configure
periodic sync timer as 6 seconds, configure the value as
6000. Default periodic sync timer value is 1 second.

Context

MIB
ARICENT-LA-MIB
OID
.1.3.6.1.4.1.2076.63.2.1.1.15
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
fsLaPortChannelEntry
Table
fsLaPortChannelTable
Siblings
42

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-90000

Related Objects

Sibling Objects