fsLaMCLAGPeriodicSyncTime

ARICENT-LA-MIB · .1.3.6.1.4.1.2076.63.1.19

Object

scalar r/w seconds Unsigned32
This object is used to configure the MC-LAG periodic sync timer
used in Active-Active Multi Chassis Link Aggregation.
Periodic sync timer is used to configure the transmission
interval of MC-LAG periodic-sync PDUs. Periodic-sync timer
will be running individually in each MC-LAG node.
          
If this object is configured with a value of '0', then no
periodic-sync messages will be sent from that MC-LAG node.
          
The configured value of this timer is applicable only
from the next start/re-start of the timer.
          
In master node, this timer is used for expiring the slave
node information and also for sending periodic update
message to all slaves.
          
Inconsistency may be observed(node addition & removal)
if master & slave periodic time differs by a long value.
          
The periodic sync timer has a period from 0 to 90 seconds,
configurable in units of seconds.
Default periodic sync timer value is 2 seconds.

Context

MIB
ARICENT-LA-MIB
OID
.1.3.6.1.4.1.2076.63.1.19
Type
scalar
Access
readwrite
Status
current
Units
seconds
Parent
fsLaSystem
Siblings
28

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 0-90

Related Objects

Sibling Objects