junidApsConfigMode

APS-MIB-JUNI · .1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.3

Object

column r/w Enumeration
The architecture of the APS group.
              
onePlusOne
              
The 1+1 architecture permanently bridges the working
line to the protection line.
              
oneToN
              
The 1:n architecture allows one protection channel to
protect up to n working channels. When a fault is detected
on one of the n working channels that channel is bridged
over the protection channel.
              
onePlusOneCompatible
              
This refers to 1 + 1 bidirectional switching compatible with
1:n bidirectional switching as specified in ITU-T
Recommendation G.783 (04/97) section A.3.4.1. Since this
mode necessitates bidirectional switching, junidApsConfigDirection
must be set to bidirectional whenever onePlusOneCompatible is set.
              
onePlusOneOptimized
              
This refers to 1 + 1 bidirectional switching optimized
for a network using predominantly 1 + 1 bidirectional
switching as specified in ITU-T Recommendation G.783 (04/97)
section B.1. Since this mode necessitates bidirectional
switching, junidApsConfigDirection must be set to bidirectional
whenever onePlusOneOptimized is set.
              
This object may not be modified if the associated
junidApsConfigRowStatus object is equal to active(1).

Context

MIB
APS-MIB-JUNI
OID
.1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.3
Type
column
Access
readwrite
Status
current
Parent
junidApsConfigEntry
Table
junidApsConfigTable
Siblings
9

Syntax

Enumeration

Values & Constraints

Enumerated Values
1onePlusOne
2oneToN
3onePlusOneCompatible
4onePlusOneOptimized

Related Objects

Sibling Objects