aluSapEthLoopbackDuration

ALU-SERVICE-MIB · .1.3.6.1.4.1.6527.6.1.2.2.6.14.1.2

Object

column r/w Unsigned32
aluSapEthLoopbackDuration is used to specify the time duration, in seconds, to set the sap
into a testhead loopback mode.  Setting aluSapEthLoopbackDuration to a non-zero value must be accompanied by 
setting aluSapEthLoopback to 'true' for the same sap.  When this timer expires,
it will be reset to the default value 0 by the system.
              
Set aluSapEthLoopbackDuration to 0 to keep the loopback mode until modified by the operator.

Context

MIB
ALU-SERVICE-MIB
OID
.1.3.6.1.4.1.6527.6.1.2.2.6.14.1.2
Type
column
Access
readwrite
Status
current
Parent
aluSapEthLoopbackEntry
Table
aluSapEthLoopbackTable
Siblings
5

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-0 range: 30-86400

Related Objects