agentBscFileSystemBootUpImage
AGENT-GENERAL-MIB ·
.1.3.6.1.4.1.171.12.1.2.18.1.1.10
Object
The result of the download will depend on whether the boot_up option has been specified.
Case 1: In the case of the master unit providing the file system and the slave unit
not providing the file system, when the boot_up parameter is specified, then the file will
be downloaded to the boot_up image on the slave. If the boot_up parameter is not specified,
then the file will not be downloaded to this slave unit.
Case 2: In the case of the master unit not providing the file system and the slave unit
providing the file system, when the boot_up parameter is specified, then the file will be downloaded
to the boot_up image on the slave unit. If boot_up is not specified, then the file will
not be downloaded to this slave unit.
Case 3: In the case of the master unit and the slave unit both supporting or not supporting the
file system, the file will be downloaded to the specified file on the slave unit. If boot_up
is specified, the downloaded file will be assigned as the boot_up image.
True: boot_up option is specified.
False: boot_up option is not specified..
Context
- MIB
- AGENT-GENERAL-MIB
- OID
.1.3.6.1.4.1.171.12.1.2.18.1.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- agentBscFileSystemEntry
- Table
- agentBscFileSystemTable
- Siblings
- 14
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| agentBscFileSystemIndex The table index for the file entry.
This object describes the file type.
runtime-code (1),
log-file (2),
cfg-file (3),
attack-log-file (7) | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.171.12.1.2.18.1.1.1 |
| agentBscFileSystemForceAgree When the force_agree option is specified, the reboot command will be executed immediately
without any further confirmation from the user.
True: force_agree option i… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.171.12.1.2.18.1.1.11 |
| agentBscFileSystemCtrl This object allows the user to download runtime software. The settings
will take effect when the system restarts. See Note (1) below
Note 1:
For systems which do no… | column | Enumeration | .1.3.6.1.4.1.171.12.1.2.18.1.1.12 |
| agentBscFileSystemInterfaceName This node is used to specify the interface name when agentBscFileSystemServerIPv6Addr
is the local link address. | column | OctetString | .1.3.6.1.4.1.171.12.1.2.18.1.1.13 |
| agentBscFileSystemServerDomainName This object indicates the domain name of the TFTP server. | column | OctetString | .1.3.6.1.4.1.171.12.1.2.18.1.1.14 |
| agentBscFileSystemIncrement If increment is specified, then the existing configuration will not be cleared before applying
of the new configuration. If it is not specified, then the existing configuration wi… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.171.12.1.2.18.1.1.15 |
| agentBscFileSystemDscr The description of the software file purpose in this entry. | column | OctetString | .1.3.6.1.4.1.171.12.1.2.18.1.1.2 |
| agentBscFileSystemServerAddr The IP address where the file to be downloaded is located, or the IP address
where the file will be uploaded to. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.171.12.1.2.18.1.1.3 |
| agentBscFileSystemServerIPv6Addr The IPv6 address where the file is to be downloaded from or uploaded to. | column | Ipv6Address | .1.3.6.1.4.1.171.12.1.2.18.1.1.4 |
| agentBscFileSystemServerFileName The name of the file to be downloaded from or uploaded to the TFTP server.
If agentBscFileSystemDeviceFileName is not set, the switch will default to using
the bootup file as… | column | OctetString | .1.3.6.1.4.1.171.12.1.2.18.1.1.5 |
| agentBscFileSystemDeviceDriverID Specifies the drive of the device that the firmware to be uploaded/downloaded is located.
If none (1) is specified, the switch will default to the current drive. | column | Enumeration | .1.3.6.1.4.1.171.12.1.2.18.1.1.6 |
| agentBscFileSystemDeviceFileName The name of the file to be downloaded to the device, or uploaded from the
device. When downloading or uploading, the agentBscFileSystemServerFileName object must also be set. | column | OctetString | .1.3.6.1.4.1.171.12.1.2.18.1.1.7 |
| agentBscFileSystemLoadType This object allows the user to select a download or upload function for the file.
Note:
For systems that do not support changes to this object, setting a value for
… | column | Enumeration | .1.3.6.1.4.1.171.12.1.2.18.1.1.8 |
| agentBscFileSystemCtrlUnitID Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from.
One or more units can be set in this list. Each bit from left to right… | column | UnitList | .1.3.6.1.4.1.171.12.1.2.18.1.1.9 |