alarmSnmpNotificationFailure
AFFIRMED-TEMS-NOTIFICATION-MIB ·
.1.3.6.1.4.1.37963.6.3.1.3.27
Object
notification
Management Server will send this notification to its NB Clients (NMS / OSS) upon its Failure to forward the trap to NB Clients registered for Trap Forwarding.
Context
- MIB
- AFFIRMED-TEMS-NOTIFICATION-MIB
- OID
.1.3.6.1.4.1.37963.6.3.1.3.27- Type
- notification
- Status
- current
- Parent
- temsNorthBoundNotifications
- Siblings
- 30
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| networkElementNotReachable Management Server will send this notification to its NB Clients (NMS / OSS) whenever
a managed network element turns unreachable (ICMP). | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.1 |
| temsServerPerfMetricMinorTCA Management Server will send this notification to its NB Clients (NMS / OSS) to report
a Minor Threshold Crossing Alert, whenever the Minor Threshold limit is
crossed for the curre… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.10 |
| temsServerPerfMetricClearTCA Management Server will send this notification to its NB Clients (NMS / OSS) to Clear
the previously raised Critical / Major / Minor TCA for this Performance Metric. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.11 |
| alarmFromNetworkElement Management Server will send this notification to its NB Clients (NMS / OSS) to report
an Alarm Raised due to the occurrence of a trap from the Network Element.
Severity List inclu… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.12 |
| hotStandbyTakesOver deprecated Indicates a Switchover of the Management server from primary to Standby Server.
Note: This alarm will be triggered only when the Management Server is deployed in a Primary - HotSt… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.13 |
| primaryServerisRestored deprecated Indicates that the Primary Management Server has been restored back in Service.
Note: This alarm will be triggered only when the Management Server is deployed in a Primary - HotSt… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.14 |
| alarmfromElementManagementSystem Management Server will send this notification to its NB Clients (NMS / OSS) to report
an Alarm Raised due to the occurence of a trap from the Network Management System.
Severity L… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.15 |
| geoRedundancyGroupMismatch Management server will send this notification to its NB clients (NMS / OSS) when it detects
mismatch information from EMS, active and standby network element
The networkElementIpA… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.16 |
| vnfScaleKpiMonitorAlarm Dynamic VM capacity management KPI monitoring alarms.
Source is cluster[vclusterId]/<KPIName> where KPIName can be
DCMSession, WSMSession, ASMConn, ASMThruput.
Severity may be of … | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.17 |
| vnfScaleOutAlarm Generated when VM scale out operation fails
Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL.
The networkElementIpAddress attribute is populated with the Mgm… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.18 |
| vnfScaleInAlarm Generated when VM scale in operation fails
Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL.
The networkElementIpAddress attribute is populated with the Mgmt… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.19 |
| networkElementNotManageable Management Server will send this notification to its NB Clients (NMS / OSS) whenever
a managed network element is reachable via ICMP but not reachable via the Management protocol … | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.2 |
| emsClusterStatusChangeNotification Management Server will send this notification to its NB Clients (NMS / OSS) upon its
detection of cluster status change | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.20 |
| alarmFromVCenter Management Server will send this notification to its NB Clients (NMS / OSS) to report
an Alarm Raised due to the occurence of a trap from VCenter Server | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.21 |
| cliLoginSuccess Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
could be login to the CLI (or TL1) session of the Network Element using the supplied
Creden… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.22 |
| cliTemplateConfigFailed Management Server will send this notification to its NB Clients (NMS / OSS) whenever
cli template configuration failed. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.23 |
| cliTemplateConfigSuccess Management Server will send this notification to its NB Clients (NMS / OSS) whenever
cli template configuration succeeds. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.24 |
| alarmtriggeredCliTemplateConfigFailed Management Server will send this notification to its NB Clients (NMS / OSS) whenever
alarm triggered cli template configuration failed. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.25 |
| alarmtriggeredCliTemplateConfigSuccess Management Server will send this notification to its NB Clients (NMS / OSS) whenever
alarm triggered cli template configuration succeeds. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.26 |
| masterSlaveStandbyNodeDown Management Server will send this notification to its NB Clients (NMS / OSS) to reports that
in cluster topology standby node moved to down state. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.28 |
| masterSlaveStandbyNodeUp Management Server will send this notification to its NB Clients (NMS / OSS) to reports that
in cluster topology standby node moved to up state. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.29 |
| networkElementManageable Management Server will send this notification to its NB Clients (NMS / OSS) to clear the
not manageable events raised previously. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.3 |
| networkElementAutoUnmanage Device has been automatically unmanaged due to authentication failure. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.32 |
| networkElementManage Device has been managed successfully. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.33 |
| unSupportedNetworkElementVersion Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
encounters / discovers a Network element running an Unsupported software version. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.4 |
| cliLoginFailed Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
could not login to the CLI (or TL1) session of the Network Element using the supplied
Crede… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.5 |
| alarmEmailNotificationFailure Management Server will send this notification to its NB Clients (NMS / OSS) upon its
Failure to send the E-Mail Notification to NB Clients registered for E-Mail Notification | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.6 |
| dataCollectionFailure Indicates a Failure during Data Collection.
NB managers can either ignore it (or) log-it. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.7 |
| temsServerPerfMetricCriticalTCA Management Server will send this notification to its NB Clients (NMS / OSS) to report
a Critical Threshold Crossing Alert, whenever the Critical Threshold limit is
crossed for the… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.8 |
| temsServerPerfMetricMajorTCA Management Server will send this notification to its NB Clients (NMS / OSS) to report
a Major Threshold Crossing Alert, whenever the Major Threshold limit is
crossed for the curre… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sourceComponent Indicates the Component within the Router / Switch responsible for the problem. It is represented in Shelf-Slot-Port format | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.8 |
| alarmDiagnosticData This is used as a place holder to include detailed alarm message | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.3 |
| temsServerTimeStamp This object specifies Time at which the Alarm is triggered by the Mgmt Server | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.37963.6.3.1.2.1 |
| alarmSeverity This object indicates the severity of alarm. Clear severity will be used
to clear the previously raised alarm | scalar | AFFIRMED-TEMS-TC-MIBAlarmLevelString | .1.3.6.1.4.1.37963.6.3.1.2.2 |
| elementHostName Includes information about the host name of the element. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.18 |