alarmFromNetworkElement
AFFIRMED-TEMS-NOTIFICATION-MIB ·
.1.3.6.1.4.1.37963.6.3.1.3.12
Object
notification
Management Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurrence of a trap from the Network Element. Severity List includes Cleared. the Clear Alarm should clear the previous raise Alarm. The combination of networkElementIPAddress, sourceComponent (if any), alarmCategory (if available) and alarmSeverity shall be used to uniquely identify a specific root cause
Context
- MIB
- AFFIRMED-TEMS-NOTIFICATION-MIB
- OID
.1.3.6.1.4.1.37963.6.3.1.3.12- Type
- notification
- Status
- current
- Parent
- temsNorthBoundNotifications
- Siblings
- 30
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| networkElementNotReachable Management Server will send this notification to its NB Clients (NMS / OSS) whenever
a managed network element turns unreachable (ICMP). | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.1 |
| temsServerPerfMetricMinorTCA Management Server will send this notification to its NB Clients (NMS / OSS) to report
a Minor Threshold Crossing Alert, whenever the Minor Threshold limit is
crossed for the curre… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.10 |
| temsServerPerfMetricClearTCA Management Server will send this notification to its NB Clients (NMS / OSS) to Clear
the previously raised Critical / Major / Minor TCA for this Performance Metric. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.11 |
| hotStandbyTakesOver deprecated Indicates a Switchover of the Management server from primary to Standby Server.
Note: This alarm will be triggered only when the Management Server is deployed in a Primary - HotSt… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.13 |
| primaryServerisRestored deprecated Indicates that the Primary Management Server has been restored back in Service.
Note: This alarm will be triggered only when the Management Server is deployed in a Primary - HotSt… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.14 |
| alarmfromElementManagementSystem Management Server will send this notification to its NB Clients (NMS / OSS) to report
an Alarm Raised due to the occurence of a trap from the Network Management System.
Severity L… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.15 |
| geoRedundancyGroupMismatch Management server will send this notification to its NB clients (NMS / OSS) when it detects
mismatch information from EMS, active and standby network element
The networkElementIpA… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.16 |
| vnfScaleKpiMonitorAlarm Dynamic VM capacity management KPI monitoring alarms.
Source is cluster[vclusterId]/<KPIName> where KPIName can be
DCMSession, WSMSession, ASMConn, ASMThruput.
Severity may be of … | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.17 |
| vnfScaleOutAlarm Generated when VM scale out operation fails
Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL.
The networkElementIpAddress attribute is populated with the Mgm… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.18 |
| vnfScaleInAlarm Generated when VM scale in operation fails
Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL.
The networkElementIpAddress attribute is populated with the Mgmt… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.19 |
| networkElementNotManageable Management Server will send this notification to its NB Clients (NMS / OSS) whenever
a managed network element is reachable via ICMP but not reachable via the Management protocol … | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.2 |
| emsClusterStatusChangeNotification Management Server will send this notification to its NB Clients (NMS / OSS) upon its
detection of cluster status change | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.20 |
| alarmFromVCenter Management Server will send this notification to its NB Clients (NMS / OSS) to report
an Alarm Raised due to the occurence of a trap from VCenter Server | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.21 |
| cliLoginSuccess Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
could be login to the CLI (or TL1) session of the Network Element using the supplied
Creden… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.22 |
| cliTemplateConfigFailed Management Server will send this notification to its NB Clients (NMS / OSS) whenever
cli template configuration failed. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.23 |
| cliTemplateConfigSuccess Management Server will send this notification to its NB Clients (NMS / OSS) whenever
cli template configuration succeeds. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.24 |
| alarmtriggeredCliTemplateConfigFailed Management Server will send this notification to its NB Clients (NMS / OSS) whenever
alarm triggered cli template configuration failed. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.25 |
| alarmtriggeredCliTemplateConfigSuccess Management Server will send this notification to its NB Clients (NMS / OSS) whenever
alarm triggered cli template configuration succeeds. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.26 |
| alarmSnmpNotificationFailure Management Server will send this notification to its NB Clients (NMS / OSS) upon its
Failure to forward the trap to NB Clients registered for Trap Forwarding. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.27 |
| masterSlaveStandbyNodeDown Management Server will send this notification to its NB Clients (NMS / OSS) to reports that
in cluster topology standby node moved to down state. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.28 |
| masterSlaveStandbyNodeUp Management Server will send this notification to its NB Clients (NMS / OSS) to reports that
in cluster topology standby node moved to up state. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.29 |
| networkElementManageable Management Server will send this notification to its NB Clients (NMS / OSS) to clear the
not manageable events raised previously. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.3 |
| networkElementAutoUnmanage Device has been automatically unmanaged due to authentication failure. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.32 |
| networkElementManage Device has been managed successfully. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.33 |
| unSupportedNetworkElementVersion Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
encounters / discovers a Network element running an Unsupported software version. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.4 |
| cliLoginFailed Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
could not login to the CLI (or TL1) session of the Network Element using the supplied
Crede… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.5 |
| alarmEmailNotificationFailure Management Server will send this notification to its NB Clients (NMS / OSS) upon its
Failure to send the E-Mail Notification to NB Clients registered for E-Mail Notification | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.6 |
| dataCollectionFailure Indicates a Failure during Data Collection.
NB managers can either ignore it (or) log-it. | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.7 |
| temsServerPerfMetricCriticalTCA Management Server will send this notification to its NB Clients (NMS / OSS) to report
a Critical Threshold Crossing Alert, whenever the Critical Threshold limit is
crossed for the… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.8 |
| temsServerPerfMetricMajorTCA Management Server will send this notification to its NB Clients (NMS / OSS) to report
a Major Threshold Crossing Alert, whenever the Major Threshold limit is
crossed for the curre… | notification | - | .1.3.6.1.4.1.37963.6.3.1.3.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| networkElementIPAddress This is used to indicate the IP-Address of the Network Element serving
as the root cause of the problem. However, if the trap is generated by the Mgmt Server
itself, this may cont… | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.37963.6.3.1.2.4 |
| sourceComponent Indicates the Component within the Router / Switch responsible for the problem. It is represented in Shelf-Slot-Port format | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.8 |
| alarmCategory Category Assigned for the Alarm. Used as a place holder to differentiate different types of
Traps that can be raised from the same component of the equipment | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.9 |
| alarmSeverity This object indicates the severity of alarm. Clear severity will be used
to clear the previously raised alarm | scalar | AFFIRMED-TEMS-TC-MIBAlarmLevelString | .1.3.6.1.4.1.37963.6.3.1.2.2 |
| alarmDiagnosticData This is used as a place holder to include detailed alarm message | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.3 |
| temsServerTimeStamp This object specifies Time at which the Alarm is triggered by the Mgmt Server | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.37963.6.3.1.2.1 |
| alarmRemedy It is used to indicate the potential impact of the alarm and corrective action to remedy. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.15 |
| alarmAdditionalInfo It contain semi-colon separated name/value pairs additional information. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.16 |
| alarmTrapOID It is used to indicate Trap OID information. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.17 |
| elementHostName Includes information about the host name of the element. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.37963.6.3.1.2.18 |