adTA5kPotsPortImpedance
ADTRAN-TA5K-POTS-MIB ·
.1.3.6.1.4.1.664.2.753.1.2.1.1.2
Object
column
r/w
Enumeration
POTS port 2-wire termination impedance - 1 = 600 Ohms 2,3 are no longer supported 4 = 900 Ohms + 2.16 uF 5 = z1 - 220 + (820 // 115nF) 6 = z2 - 270 + (750 // 150nF) 7 = z3 - 270 + (750 // 150nF), Zin = 600r 8 = z4 - 320 + (1050 // 230nF) 9 = z5 - 350 + (1000 // 210nF), Zin = 600r 10 = z6 - 370 + (620 // 310nF) 11 = z7 - 800 // (100 + 50nF), Zin = 900c 12 = z8 - 1650 // (100 + 5nF), Zin = 900c
Context
- MIB
- ADTRAN-TA5K-POTS-MIB
- OID
.1.3.6.1.4.1.664.2.753.1.2.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- adTA5kPotsPortProvEntry
- Table
- adTA5kPotsPortProvTable
- Siblings
- 17
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | ohm600 |
2 | ohm900 |
3 | ohm600Plus216uF |
4 | ohm900Plus216uF |
5 | ohmz1 |
6 | ohmz2 |
7 | ohmz3 |
8 | ohmz4 |
9 | ohmz5 |
10 | ohmz6 |
11 | ohmz7 |
12 | ohmz8 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adTA5kPotsPortMode POTS port operational Mode -
1 = Loopstart
2 = Groundstart
3 = TR08 Single Party
4 = TR08 UVG | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.1 |
| adTA5kPotsPortImpedanceByLoopLength POTS port 2-wire termination impedance by loop length-
1 = Other - The impedance matches one of the values defined by adTA5kPotsPortImpedance that
can not be accurately represente… | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.10 |
| adTA5kPotsPortOverTempAlarmEnable Provisioning for Enable/Disable Over Temperature Alarm which is a port level alarm.
1 = Enable
2 = Disable | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.11 |
| adTA5kPotsPortMwiType Provisioning for the type of Message Waiting Indication for this port to use.
1 = Use Frequency Shift Keying (FSK) to indicate Message Waiting to the phone
2 = Use Neon Voltage to… | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.12 |
| adTA5kPotsPortNeonMwiCadence Provisioning for the flashing cadence of Neon Message Waiting Indication for this port.
1 = Flash the Neon lamp on or off every 1000ms
2 = Flash the Neon lamp on or off every 500m… | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.13 |
| adTA5kPotsPortNeonMwiVoltage Provisioning for the voltage of Neon Message Waiting Indication for this port.
1 = 85 volts
2 = 90 volts
3 = 100 volts
4 = 110 volts
5 = 120 volts
6 = 130 volts | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.14 |
| adTA5kPotsPortVoiceCallJitterBufferDepth Provisioning for the Jitter Buffer Depth used for Voice Calls in mS | column | Integer32 | .1.3.6.1.4.1.664.2.753.1.2.1.1.15 |
| adTA5kPotsPortFaxModemCallJitterBufferDepth Provisioning for the Jitter Buffer Depth used for Fax Modem Calls in mS | column | Integer32 | .1.3.6.1.4.1.664.2.753.1.2.1.1.16 |
| adTA5kPotsPortCircuitIdentifier The circuit identifier string for the fxs port. | column | OctetString | .1.3.6.1.4.1.664.2.753.1.2.1.1.17 |
| adTA5kPotsPulseDigitDetectionEnable This entry is used to enable or disable the pulse dial digit detection for this port.
This entry only applies to fxs ports that are connected to a VoIP service, such as SIP or MGC… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.664.2.753.1.2.1.1.18 |
| adTA5kPotsPortTXTLPString POTS Port Transmit TLP -9.0dB to +6.0dB | column | OctetString | .1.3.6.1.4.1.664.2.753.1.2.1.1.3 |
| adTA5kPotsPortRXTLPString POTS Port Receive TLP -10.0dB to +6.0dB | column | OctetString | .1.3.6.1.4.1.664.2.753.1.2.1.1.4 |
| adTA5kPotsPortOnHookMsg POTS Port On-Hook Messaging -
1 = Enable
2 = Disable | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.5 |
| adTA5kPotsPortTrunkConditioningAlarm Provisioning for Enable/Disable Trunk Conditioning Alarm which is a port level alarm.
1 = Enable
2 = Disable | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.6 |
| adTA5kPotsPortLineShoweringAlarm Provisioning for Enable/Disable Line Showering Alarm which is a port level alarm.
1 = Enable
2 = Disable | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.7 |
| adTA5kPotsPortAutoImpedanceMode POTS Automatic Impedance Mode -
1 = Manual
2 = Automatic | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.8 |
| adTA5kPotsPortRingVoltage POTS Ringer Voltage -
1 = 50 Vrms
2 = 60 Vrms
3 = 70 Vrms
4 = 80 Vrms
5 = 85 Vrms
6 = 90 Vrms | column | Enumeration | .1.3.6.1.4.1.664.2.753.1.2.1.1.9 |