adGenBridgeProtectionPriority
ADTRAN-GENERIC-BRIDGE-MIB ·
.1.3.6.1.4.1.664.5.67.1.16.1.10.1.6
Object
column
r/w
Integer32
This is the priority of the Protected Modules within the protection group in case priority protection is enabled. This value can be set to zero. If all the Protected Modules priority is set to zero then priority protection is disabled. Protected Modules with in a group can have equal priority. This item is not intended for the Protection Module and is ignored.
Context
- MIB
- ADTRAN-GENERIC-BRIDGE-MIB
- OID
.1.3.6.1.4.1.664.5.67.1.16.1.10.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- adGenBridgeProtectionEntry
- Table
- adGenBridgeProtectionTable
- Siblings
- 10
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-32
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adGenBridgeProtectionGroupIndex Displays the Protection Group Index this slot is part of. If this slot
is not part of any Protection Group, then this value will be zero. | column | Integer32 | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.1 |
| adGenBridgeProtectionManualSwitchTime In case a manual switch is triggered, this time in minutes
indicates for how long the manual switch will be in effect. This
item is not intended for the Protection Module and is i… | column | Integer32 | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.10 |
| adGenBridgeProtectionErrorStatus Displays error status in case the manual switch command fails. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.11 |
| adGenBridgeProtectionBridgeType This is the value read from the module that is plugged into the slot. If bridge
type of this module is incompatible with the Bridge Type of the Protection
Group this module is par… | column | AdGenBridgeType | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.2 |
| adGenBridgeProtectionVersion This must be compatible with Protection and Protected Modules. A higher
version Protection Module can protect a lower or equal version Protected
module. This versioning is done to… | column | AdGenProtectionVersion | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.3 |
| adGenBridgeProtectionSlot This is a read only value and indicates the slot number of this entry. | column | Integer32 | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.4 |
| adGenBridgeProtectionState This is a read only value and indicates state of the Protection or Protected Module.
A value of zero indicates the module plugged into this slot is not being protected
or is not p… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.5 |
| adGenBridgeProtectionRevertiveSwitch Indicates whether revertive switch is enabled or not for this Protected
Module. This item is not intended for the Protection Module and is ignored. | column | AdGenBridgeProtectionRevertiveSwitch | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.7 |
| adGenBridgeProtectionLockout Indicates whether lockout is enabled or not for this Module. | column | AdGenBridgeProtectionLockout | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.8 |
| adGenBridgeProtectionManualSwitch Indicates whether to do a manual switch to protection or to manual switch
back from protect. Not intended for the Protection Module and is ignored. | column | AdGenBridgeManualSwitch | .1.3.6.1.4.1.664.5.67.1.16.1.10.1.9 |