adGenBridgeNeedsProtectionAlmCLR
ADTRAN-GENERIC-BRIDGE-MIB ·
.1.3.6.1.4.1.664.5.67.1.16.3.0.6
Object
notification
Access Module Needs-Protection
Context
- MIB
- ADTRAN-GENERIC-BRIDGE-MIB
- OID
.1.3.6.1.4.1.664.5.67.1.16.3.0.6- Type
- notification
- Status
- current
- Parent
- adGenBridgeAlarms
- Siblings
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adGenBridgeLockoutProtectionAlmCLR Access Module Protection Lockout | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.10 |
| adGenBridgeLockoutProtectionAlmACT Access Module Protection Lockout | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.11 |
| adGenBridgeNonProtectedAlmCLR Access Module Non-Protected | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.2 |
| adGenBridgeNonProtectedAlmACT Access Module Non-Protected | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.3 |
| adGenBridgeProtectedAlmCLR Access Module Protected | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.4 |
| adGenBridgeProtectedAlmACT Access Module Protected | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.5 |
| adGenBridgeNeedsProtectionAlmACT Access Module Needs Protection | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.7 |
| adGenBridgeManualProtectionAlmCLR Access Module ManualSwitch Protection | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.8 |
| adGenBridgeManualProtectionAlmACT Access Module ManualSwitch Protection | notification | - | .1.3.6.1.4.1.664.5.67.1.16.3.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum The sequence number included in the last trap originated by
this device. This can be used to confirm receipt of the
latest traps. Not needed by SNMPv2 Informs. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.16.1.2 |
| SNMPv2-MIBsysName An administratively-assigned name for this managed
node. By convention, this is the node's fully-qualified
domain name. If the name is unknown, the value is
the zero-length stri… | scalar | OctetString | .1.3.6.1.2.1.1.5 |
| ADTRAN-GENSLOT-MIBadGenSlotInfoIndex A unique value for each slot. Its value may exceed
the value of adGenSlotNumber if pseudo slot numbers
are used for some bank commons or multiplexers.
This object is visible for … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.13.2.3.1.1 |
| IF-MIBifIndex A unique value, greater than zero, for each interface. It
is recommended that values are assigned contiguously
starting from 1. The value for each interface sub-layer
must remai… | column | InterfaceIndex | .1.3.6.1.2.1.2.2.1.1 |